Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

被引:0
作者
Patel, Chirag D. [1 ,2 ]
Guttikar, Swati [1 ]
Patel, Bhavesh H. [2 ]
机构
[1] Veeda Clin Res, Bioanalyt Res Dept, Ahmadabad 380059, Gujarat, India
[2] KBIPER, Dept Pharmaceut Chem, Sect 23, Gandhinagar, Gujarat, India
来源
ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH | 2018年 / 5卷 / 01期
关键词
Bioanalytical method; Nebivolol enantiomers; Human plasma; LC-MS/MS;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes from human plasma were extracted by ion exchange cartridges and subsequently separated on chiral column using acetonitrile: ammonium carbonate in water, 158 mg l(-1) 80: 20% v/v as a mobile phase, at a flow rate of 0.9 ml min(-1). Quantification of SRRR and R-SSS nebivolol and R-nebivolol D4 was performed using multi-reaction monitoring mode (MRM) in positive mode. The calibration curve was linear (r(2) > 0.99) over the concentration range of 20.0-6000 pg ml(-1) for S-RRR and R-SSS nebivolol. The intra-day and inter-day assay precision revealed within +/- 15% (at LLOQ level +/- 20%) with accuracy within 85-115% (at LLOQ level 80-120%). The LC-MS/MS method was fully validated for all the validation parameters as per current regulatory requirement (US FDA, EU) such as selectivity, matrix effect, recovery and stability (in solution and in matrix stability). Overall the present study revealed the selectivity and sensitivity of this method for the simultaneous estimation of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma.
引用
收藏
页码:131 / 142
页数:12
相关论文
共 17 条
  • [1] Ang S. F., 2010, BIOL, V30, P963
  • [2] Comparison of the Usefulness of SPE Cartridges for the Determination of β-Blockers and β-Agonists (Basic Drugs) in Environmental Aqueous Samples
    Caban, Magda
    Stepnowski, Piotr
    Kwiatkowski, Marek
    Maszkowska, Joanna
    Wagil, Marta
    Kumirska, Jolanta
    [J]. JOURNAL OF CHEMISTRY, 2015, 2015
  • [3] Chankvetadze Bezhan, 2013, Methods Mol Biol, V970, P81, DOI 10.1007/978-1-62703-263-6_5
  • [4] European Medicines Agency (EMA), 2011, GUIDELINE BIOANALYTI
  • [5] A Review of Nebivolol Pharmacology and Clinical Evidence
    Fongemie, Justin
    Felix-Getzik, Erika
    [J]. DRUGS, 2015, 75 (12) : 1349 - 1371
  • [6] Location of the hydroxyl functions in hydroxylated metabolites of nebivolol in different animal species and human subjects as determined by on-line high-performance liquid chromatography diode-array detection
    Hendrickx, J
    Bockx, M
    Zwijsen, C
    Borgmans, C
    Mannens, G
    Meuldermans, W
    Heykants, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) : 341 - 354
  • [7] Nebivolol: Vasodilator Properties and Evidence for Relevance in Treatment of Cardiovascular Disease
    Howlett, Jonathan G.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2014, 30 (05) : S29 - S37
  • [8] Kachhadia PK, 2008, J AOAC INT, V91, P557
  • [9] Lindamood C., 2011, J CLIN PHARMACOL, V514, P1253
  • [10] Quantitative determination of nebivolol from human plasma using liquid chromatography-tandem mass spectrometry
    Nandania, Jatin
    Rajput, S. J.
    Contractor, Pritesh
    Vasava, Pragnesh
    Solanki, Bhavik
    Vohra, Mohsin
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 923 : 110 - 119