CLINICAL-EVALUATION OF CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITORING - ACCURACY AND TRACKING CAPABILITIES

被引:43
作者
YOUNG, CC
MARK, JB
WHITE, W
DEBREE, A
VENDER, JS
FLEMING, A
机构
[1] From the Department of Anesthesiology, Durham Veterans Affairs Medical Center, Durham, NC
[2] From the Department of Anesthesiology, Duke University Medical Center, Durham, NC
[3] From the Department of Anesthesiology, Duke University Medical Center, Durham, 27710, NC
[4] From the Department of Anesthesiology, Evanston Memorial Hospital, Evanston, IL
[5] From the Department of Anesthesiology, St Vincent's Hospital, Indianapolis, IN
来源
JOURNAL OF CLINICAL MONITORING | 1995年 / 11卷 / 04期
关键词
BLOOD PRESSURE; DETERMINATION; EQUIPMENT; MONITORS; MONITORING; INTRAOPERATIVE;
D O I
10.1007/BF01617519
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A continuous, noninvasive device for blood pressure measurement using pulse transit time has been recently introduced. We compared blood pressure measurements determined using this device with simultaneous invasive blood pressure measurements in 35 patients undergoing general endotracheal anesthesia. Data were analyzed for accuracy and tracking ability of the noninvasive technique, and for frequency of unavailable pressure measurements by each method. A total of 25,133 measurements of systolic pressure, diastolic pressure, and mean arterial pressure (MAP) by each method were collected for comparison from 35 patients. Accuracy was expressed by reporting mean bias (invasive pressure minus noninvasive pressure) and limits of agreement between the two measurements. After correction for the offset found when measuring invasive and oscillometric methods of arterial pressure measurement, the mean biases for systolic, diastolic, and mean pressures by the pulse wave method were -0.37 mm Hg, -0.01 mm Hg, and -0.05 mm Hg, respectively (p < 0.001). The limits of agreement were: -29.0 to 28.2 mm Hg, -14.9 to 14.8 mm Hg, and -19.1 to 19.0 mm Hg, respectively (95% confidence intervals). When blood pressure measured invasively changed over time by more than 10 mm Hg, the noninvasive technique accurately tracked the direction of change 67% of the time. During the entire study, 3.2% of the invasive measurements were unavailable and 12.9% of the noninvasive measurements were unavailable. The continuous noninvasive monitoring technique is not of sufficient accuracy to replace direct invasive measurement of arterial blood pressure, owing to relatively wide limits of agreement between the two methods. The continuous noninvasive method may serve as an intermediate technology between intermittent noninvasive and continuous invasive measurement of blood pressure if tracking capabilities can be improved; but, further refinement is needed before it can be recommended for routine intraoperative use.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 29 条
[1]  
ASA standards, guidelines and statements, pp. 4-5, (1993)
[2]  
Showman A., Betts E.K., Hazard of automatic noninvasive blood pressure monitoring, Anesthesiology, 55, pp. 717-718, (1981)
[3]  
Sy W.P., Ulnar nerve palsy possibly related to use of automatically cycled blood pressure cuff, Anesth Analg, 60, pp. 687-688, (1981)
[4]  
Pinilla J.C., Ross D.F., Martin T., Crump H., Study of the incidence of intravascular catheter infection and associated septicemia in critically ill patients, Crit Care Med, 11, pp. 21-25, (1983)
[5]  
Puri V.K., Carlson R.W., Bander J.J., Wei M.H., Complications of vascular catheterization in the critically ill: A prospective study, Crit Care Med, 8, pp. 495-499, (1980)
[6]  
Shenoy P.N., Leaman D.M., Field J.M., Safety of short term percutaneous arterial cannulation, Anesth Analg, 58, pp. 256-262, (1979)
[7]  
Mangano D.T., Hickey R.F., Ischemic injury following uncomplicated radial artery catheterization, Anesth Analg, 58, pp. 55-57, (1979)
[8]  
Maier W.R., Noninvasive blood pressure monitoring, Monitoring in anesthesia and critical care medicine, pp. 35-40, (1985)
[9]  
Bland J.M., Altman D.G., Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, 1, pp. 307-310, (1986)
[10]  
O'Rourke M.F., Yaginuma T., Wave reflections and the arterial pulse, Arch Intern Med, 144, pp. 366-371, (1984)