IN-LINE FILTRATION OF PLATELET CONCENTRATES OBTAINED WITH THE OMNIX(TM) BLOOD-CELL SEPARATOR

被引:5
作者
MOOG, R
MULLER, N
NIEPER, A
机构
[1] Institute for Transfusion Medicine, University Clinics, Essen
关键词
LEUKOCYTE FILTRATION; PLATELETPHERESIS; PRODUCT QUALITY;
D O I
10.1111/j.1365-3148.1995.tb00218.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The quality of platelet concentrates (PC) obtained with the blood cell separator Omnix(TM) was investigated before and after in-line filtration. PC were filtered 2 h (protocol A) and 4 h (protocol B) after the termination of apheresis. Platelet (PLT) yield after filtration was similar in both protocols (median 3.7 vs. 3.4 x 10(11)). Median white blood cell (WBC) contamination after leucocyte depletion was 0.07 x 10(6) (range 0.02-3.27 x 10(6)) in protocol A and 0.06 x 10(6) (range 0.02-2.1 x 10(6)) in protocol B. Glucose, lactate, lactate dehydrogenase, morphology score and pH value were not statistically different before and after filtration in both protocols. We conclude that in-line filtration results in sufficient leucocyte depletion of the PC. The prefiltration storage time did not influence the studied parameters of product quality.
引用
收藏
页码:293 / 296
页数:4
相关论文
共 22 条
  • [1] ANDREU G, 1991, SEMIN HEMATOL, V28, P22
  • [2] ANDREU G, 1988, BLOOD, V72, P964
  • [3] BAUDOUX E, 1994, VOX SANGUINIS S2, V67, P71
  • [4] STORAGE OF SINGLE-DONOR PLATELET CONCENTRATES - METABOLIC AND FUNCTIONAL-CHANGES
    BOCK, M
    GLASER, A
    PFOSSER, A
    SCHLEUNING, M
    HEIM, MU
    MEMPEL, W
    [J]. TRANSFUSION, 1993, 33 (04) : 311 - 315
  • [5] PLATELETPHERESIS - COMPARISON OF PLATELET YIELDS, PROCESSING TIME, AND WHITE CELL CONTENT WITH 2 APHERESIS SYSTEMS
    BURGSTALER, EA
    PINEDA, AA
    BRECHER, MA
    [J]. TRANSFUSION, 1993, 33 (05) : 393 - 398
  • [6] ALLOIMMUNIZATION TO HLA ANTIGENS FOLLOWING TRANSFUSION WITH LEUKOCYTE-POOR AND PURIFIED PLATELET SUSPENSIONS
    FISHER, M
    CHAPMAN, JR
    TING, A
    MORRIS, PJ
    [J]. VOX SANGUINIS, 1985, 49 (05) : 331 - 335
  • [7] 1ST RESULTS WITH THE NEW FRESENIUS CELL SEPARATOR AS-104
    KRETSCHMER, V
    SEE, A
    SOHNGEN, D
    BACHEM, M
    KADAR, JG
    BORBERG, H
    PELZER, H
    ZOFEL, P
    [J]. PLASMA THERAPY & TRANSFUSION TECHNOLOGY, 1987, 8 (04): : 298 - 301
  • [8] KRETSCHMER V, 1991, INFUSIONSTHERAPIE, V18, P188
  • [9] KUNICKI TJ, 1975, TRANSFUSION, V15, P141
  • [10] COMPARISON OF PLATELETPHERESIS WITH A STANDARD AND AN IMPROVED COLLECTION DEVICE
    MARESH, S
    RANDELS, MJ
    STRAUSS, RG
    WINEGARDEN, D
    LUDWIG, GA
    [J]. TRANSFUSION, 1993, 33 (10) : 835 - 837