FAILURE OF THE KETY-SCHMIDT NITROUS-OXIDE METHOD FOR DETERMINATION OF MYOCARDIAL BLOOD-FLOW

被引:6
作者
REID, MA [1 ]
MATHER, LE [1 ]
RUNCIMAN, WB [1 ]
MCLEAN, CF [1 ]
机构
[1] FLINDERS UNIV,MED CTR,DEPT ANAESTHESIA & INTENS CARE,BEDFORD PK,SA 5042,AUSTRALIA
关键词
CARDIOVASCULAR SYSTEM; KETY-SCHMIDT METHOD; NITROUS OXIDE-BLOOD CONCENTRATION ANALYSIS; NITROUS OXIDE-PHARMACOKINETICS; REGIONAL BLOOD FLOW-MYOCARDIUM; SHEEP;
D O I
10.1111/j.1440-1681.1991.tb01428.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
1. The reliability of the Kety-Schmidt nitrous oxide (N2O) blood-tissue equilibration method was examined in 50 studies of myocardial blood flow in seven conscious, unrestrained sheep using a newly developed carefully validated gas chromatographic assay for N2O. 2. In 10 studies the arterial and coronary sinus N2O blood concentration-time curves converged as expected at the end of the 10 min sampling period. In 14 studies they crossed over, and in 26 studies, the curves failed to converge. 3. A survey of the literature revealed that such results have been encountered previously but have not been accorded particular significance. An ultimate matching equilibrium between arterial and venous blood N2O concentration-time curves is, however, fundamental to the validity of the method. 4. The results indicate that the use of the Kety-Schmidt method with N2O as the indicator gas is invalid as applied to the measurement of myocardial blood flow in this preparation.
引用
收藏
页码:169 / 178
页数:10
相关论文
共 24 条