HIGHLY SENSITIVE METHOD FOR UREA DETECTION IN WINE

被引:17
|
作者
KODAMA, S
SUZUKI, T
机构
[1] Vitamin & Food Research Laboratories, Vitamin & Food Division, Takeda Chemical Industries, Ltd, Osaka, 532, 17–85, JusoHonmachi Yodogawa-ku
关键词
WINE; UREA; HPLC; FLUOROMETRIC; BEVERAGES;
D O I
10.1111/j.1365-2621.1995.tb06300.x
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Trace amounts of urea (less than 50 mu g/L) in wine were accurately determined using a modified high performance liquid chromatography (HPLC-fluorometric) technique. Appropriate selection of eluent, HPLC columns, and chiral derivatives for the o-phthalaldehyde solution provided a 20-fold enhancement of sensitivity over established methods. A linear relationship was observed at concentrations from 0.5-500 mu g/L of aqueous urea solution. The threshold level for detectability of urea in wine was 5 mu g/L. The method is simple enough to be applicable to most beverages.
引用
收藏
页码:1097 / &
相关论文
共 50 条
  • [41] Highly sensitive detection for cocaine using an aptamer-cocaine-aptamer method
    Gao, Li
    Wang, Huixing
    Deng, Zebin
    Xiang, Wenwen
    Shi, Haifeng
    Xie, Bing
    Shi, Haixia
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (06) : 2571 - 2577
  • [42] HIGHLY SENSITIVE ELECTROIMMUNODIFFUSION METHOD OF ANTIGEN DETECTION ON CELLULOSE-ACETATE FILMS
    ABELEV, GI
    SOKOLENKO, AA
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1977, 84 (07) : 1065 - 1068
  • [43] Protocol: a highly sensitive RT-PCR method for detection and quantification of microRNAs
    Erika Varkonyi-Gasic
    Rongmei Wu
    Marion Wood
    Eric F Walton
    Roger P Hellens
    Plant Methods, 3
  • [44] Communication-Highly Sensitive Ag/ZnO Nanorods Composite Electrode for Non-Enzymatic Urea Detection
    Yoon, Jaesik
    Lee, Eunji
    Lee, Doohee
    Oh, Tae-Sik
    Yoon, Young Soo
    Kim, Dong-Joo
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (12) : B558 - B560
  • [45] Detection of apoptosis in myelodysplastic syndrome with an in situ end labeling method and a highly sensitive DNA ladder detection method.
    Arimura, K
    Arima, N
    Matsushita, K
    Ohtsubo, H
    Kukita, T
    Suruga, Y
    Wakamatsu, S
    Fujiwara, H
    Hidaka, S
    BLOOD, 1997, 90 (10) : 4024 - 4024
  • [46] Highly sensitive detection of lead ions
    不详
    GOLD BULLETIN, 2008, 41 (04): : NTGN12 - NTGN12
  • [47] Highly sensitive detection of inorganic contamination
    Beckhoff, B.
    Nutsch, A.
    Altmann, R.
    Borionetti, G.
    Pello, C.
    Polignano, M. L.
    Codegoni, D.
    Grasso, S.
    Cazzini, E.
    Bersani, M.
    Lazzeri, P.
    Gennaro, S.
    Kolbe, M.
    Mueller, M.
    Kregsamer, P.
    Posch, F.
    ULTRA CLEAN PROCESSING OF SEMICONDUCTOR SURFACES IX: UCPSS 2008-9TH INTERNATIONAL SYMPOSIUM ON ULTRA CLEAN PROCESSING OF SEMICONDUCTOR SURFACES (UCPSS), 2009, 145-146 : 101 - +
  • [48] A facile and highly sensitive resonance Rayleigh scattering-energy transfer method for urea using a fullerene probe
    Yao, Dongmei
    He, Zining
    Wen, Guiqing
    Liang, Aihui
    Jiang, Zhiliang
    RSC ADVANCES, 2018, 8 (51): : 29008 - 29012
  • [49] A colourimetric fluorescent probe for the sensitive detection of total iron in wine
    Duan, Ning
    Feng, Jingyi
    Deng, Bing
    Yang, Shaoxiang
    Tian, Hongyu
    Sun, Baoguo
    FOOD CHEMISTRY, 2022, 383
  • [50] Highly sensitive urea sensing with ion-irradiated polymer foils
    Fink, Dietmar
    Hernandez, Gerardo Munoz
    Alfonta, Lital
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 273 : 164 - 170