A PARAMETRIC STUDY OF THE FACTORS AFFECTING THE FATIGUE-STRENGTH OF POROUS COATED TI-6AL-4V IMPLANT ALLOY

被引:40
作者
KOHN, DH [1 ]
DUCHEYNE, P [1 ]
机构
[1] UNIV PENN, DEPT BIOENGN, PHILADELPHIA, PA 19104 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1990年 / 24卷 / 11期
关键词
D O I
10.1002/jbm.820241106
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The high cycle fatigue strength of porous coated Ti‐6Al‐4V is approximately 75% less than the fatigue strength of uncoated Ti‐6Al‐4V. This study separates the effects of three parameters thought to be responsible for this reduction: interfacial geometry, microstructure, and surface alternations brought about by sintering. To achieve the goal of one parameter variations, hydrogen‐alloying treatments, which refined the lamellar microstructure of β‐annealed and porous coated Ti‐6Al‐4V, were formulated. The fatigue strength of smooth‐surfaced Ti‐6Al‐4V subjected to hydrogen‐alloying treatments is 643–669 MPa, significantly greater than the fatigue strength of β‐annealed Ti‐6Al‐4V (497 MPa) and also greater than the fatigue strength of preannealed, equiaxed Ti‐6Al‐4V (590 MPa). The fatigue strength of porous coated Ti‐6Al‐4V, however, is independent of microstructure. This leads to the conclusion that the notch effect of the surface porosity does not allow the material to take advantage of the superior fatigue crack initation resistance of a refined α‐grain size. Thus, sinternecks act as initiated microcracks and fatigue of porous coated Ti‐6Al‐4V is propagation controlled. Copyright © 1990 John Wiley & Sons, Inc.
引用
收藏
页码:1483 / 1501
页数:19
相关论文
共 44 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   LOAD INTERACTION EFFECTS ON COMPRESSION FATIGUE CRACK-GROWTH IN DUCTILE SOLIDS [J].
ASWATH, PB ;
SURESH, S ;
HOLM, DK ;
BLOM, AF .
JOURNAL OF ENGINEERING MATERIALS AND TECHNOLOGY-TRANSACTIONS OF THE ASME, 1988, 110 (03) :278-285
[3]   CONSTITUTIVE BEHAVIOR OF A MICROCRACKING BRITTLE SOLID IN CYCLIC COMPRESSION [J].
BROCKENBROUGH, JR ;
SURESH, S .
JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 1987, 35 (06) :721-742
[4]   EXCESSIVE METAL RELEASE DUE TO LOOSENING AND FRETTING OF SINTERED PARTICLES ON POROUS-COATED HIP PROSTHESES - REPORT OF 2 CASES [J].
BUCHERT, PK ;
VAUGHN, BK ;
MALLORY, TH ;
ENGH, CA ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (04) :606-609
[5]   THE UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS - 2-YEAR RESULTS OF A PROSPECTIVE CONSECUTIVE SERIES [J].
CALLAGHAN, JJ ;
DYSART, SH ;
SAVORY, CG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :337-346
[6]  
CAMERON HU, 1986, CLIN ORTHOP RELAT R, P81
[7]   LOOSENING OF THE POROUS COATING IN TOTAL KNEE REPLACEMENT [J].
CHENG, CL ;
GROSS, AE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :377-381
[8]   THE EFFECT OF POST-SINTERING HEAT-TREATMENTS ON THE FATIGUE PROPERTIES OF POROUS COATED TI-6AL-4V ALLOY [J].
COOK, SD ;
THONGPREDA, N ;
ANDERSON, RC ;
HADDAD, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (04) :287-302
[9]   FATIGUE PROPERTIES OF CARBON-COATED AND POROUS-COATED TI-6AL-4V ALLOY [J].
COOK, SD ;
GEORGETTE, FS ;
SKINNER, HB ;
HADDAD, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (05) :497-512
[10]  
DAVEY JR, 1988, CLIN ORTHOP RELAT R, P97