NON-RAYLEIGH 1ST-ORDER STATISTICS OF ULTRASONIC BACKSCATTER FROM NORMAL MYOCARDIUM

被引:43
|
作者
CLIFFORD, L
FITZGERALD, P
JAMES, D
机构
[1] UNIV CALIF SAN FRANCISCO,SCH MED,SAN FRANCISCO,CA 94143
[2] DARTMOUTH COLL,HITCHCOCK MED CTR,HANOVER,NH 03756
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1993年 / 19卷 / 06期
关键词
PROBABILITY DISTRIBUTION FUNCTION (PDF); NON-RAYLEIGH PDF; ULTRASONIC BACKSCATTER; NORMAL MYOCARDIUM;
D O I
10.1016/0301-5629(93)90124-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Historically, it has been assumed that the first-order envelope statistics of ultrasonic backscatter from myocardium are best described by the Rayleigh probability distribution function (PDF); however, few studies have tested this assumption. This study compares the ability of five PDFs, including the Rayleigh, to describe high-frequency (5-15 MHz) ultrasonic backscatter from in vivo canine myocardium and in vitro human myocardium. The PDFs used have all been previously proposed as descriptions of backscatter from parenchymal tissue or other random media. In this study goodness-of-fit testing of backscatter recorded at several frequencies and insonification angles shows that only in a minority of cases is the envelope Rayleigh-distributed. In most cases, the K distribution provides the best fit. In addition, computer simulation, shows that sparse Poisson scattering can produce K-distributed backscatter. Scattering of this type may contribute to the observed non-Rayleigh character of myocardial backscatter. We conclude that the Rayleigh distribution is not an adequate description of backscatter from myocardium. Non-Rayleigh distributions may offer an additional approach to myocardial tissue characterization.
引用
收藏
页码:487 / 495
页数:9
相关论文
共 50 条
  • [1] 1ST-ORDER STATISTICS OF A NON-RAYLEIGH FADING SIGNAL AND ITS DETECTION
    JAO, JK
    ELBAUM, M
    PROCEEDINGS OF THE IEEE, 1978, 66 (07) : 781 - 789
  • [2] NON-RAYLEIGH STATISTICS OF ULTRASONIC BACKSCATTERED SIGNALS
    NARAYANAN, VM
    SHANKAR, PM
    REID, JM
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (06) : 845 - 852
  • [3] Studies on the use of non-Rayleigh statistics for ultrasonic tissue characterization
    Shankar, PM
    Molthen, R
    Narayanan, VM
    Reid, JM
    Genis, V
    Forsberg, F
    Piccoli, CW
    Lindenmayer, AE
    Goldberg, BB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07): : 873 - 882
  • [4] CHARACTERIZATION OF ULTRASONIC B-SCANS USING NON-RAYLEIGH STATISTICS
    MOLTHEN, RC
    SHANKAR, PM
    REID, JM
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02): : 161 - 170
  • [5] USE OF NON-RAYLEIGH STATISTICS FOR THE IDENTIFICATION OF TUMORS IN ULTRASONIC B-SCANS OF THE BREAST
    SHANKAR, PM
    REID, JM
    ORTEGA, H
    PICCOLI, CW
    GOLDBERG, BB
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 687 - 692
  • [6] STATISTICS OF EXTREME VALUES OF A 1ST-ORDER MARKOV NORMAL PROCESS - AN EXACT RESULT
    CHOCK, DP
    ATMOSPHERIC ENVIRONMENT, 1984, 18 (11) : 2461 - 2470
  • [8] THE 1ST-ORDER STATISTICS OF SPECKLE INTENSITY VARIATIONS
    OHTSUBO, J
    JOURNAL OF MECHANICAL ENGINEERING LABORATORY, 1980, 34 (04): : 165 - 180
  • [9] ULTRASONIC ANISOTROPY OF BACKSCATTER FROM NORMAL MYOCARDIUM IS VIEW-DEPENDENT
    SHEPARD, RK
    RECCHIA, D
    MILLER, JG
    WICKLINE, SA
    CIRCULATION, 1992, 86 (04) : 18 - 18
  • [10] MECHANISMS OF THE VIEW-DEPENDENCE OF ULTRASONIC BACKSCATTER FROM NORMAL MYOCARDIUM
    RECCHIA, D
    HALL, CS
    SHEPARD, RK
    MILLER, JG
    WICKLINE, SA
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (01) : 91 - 98