CHARACTERIZATION AND OPTIMIZATION OF HPIC FOR ONLINE PRECONCENTRATION OF TRACE-METALS WITH DETECTION BY ICP MASS-SPECTROMETRY

被引:23
作者
BOOMER, DW [1 ]
POWELL, MJ [1 ]
HIPFNER, J [1 ]
机构
[1] ONTARIO MINIST ENVIRONM,INORGAN TRACE CONTAMINANTS SECT,125 RESOURCES RD,REXDALE M9W 5L1,ONTARIO,CANADA
关键词
D O I
10.1016/0039-9140(90)80053-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The objective of this study was to investigate the feasibility of using a commercially available cation-exchange column for trace metal preconcentration. In addition, the advantages of interfacing the column to a highly sensitive element-selective detector were examined. A high-performance ion-chromatograph (HPIC) with a high-pressure pump and valve system was used to aid loading and delivery of the mobile phase. An inductively coupled plasma mass spectrometer combination (ICP-MS) was used as a detection device, with interfacing by means of a small diameter liquid-transport tube. The performance of the HPIC/ICP-MS combination was optimized by varying the concentration and flow-rate of two eluents (nitric acid and hydrochloric acid). The effects of varying the sample pH were assessed and the column capacity was determined by "breakthrough" tests. The elements copper, cadmium, mercury and lead were studied; the detection capability was dependent upon the sample volume loaded onto the column. The accuracy of the method was assessed by analysis of an "in house" reference standard. © 1987.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 33 条
[21]   THE SPECTROPHOTOMETRIC DETERMINATION OF PHOSPHATE AND ARSENATE BY SELECTIVE EXTRACTION WITH MIXED-SOLVENTS [J].
SHIDA, J ;
KAKIZAKI, S ;
HOZUMI, Y ;
ITOH, A ;
MATSUO, T .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1983, 56 (02) :633-634
[22]   CONTINUUM SOURCE ATOMIC FLUORESCENCE DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
SIEMER, DD ;
KOTEEL, P ;
HAWORTH, DT ;
TARASZEWSKI, WJ ;
LAWSON, SR .
ANALYTICAL CHEMISTRY, 1979, 51 (04) :575-579
[23]   HITACHI GRAPHITE FURNACE ZEEMAN ATOMIC-ABSORPTION SPECTROMETER AS AN AUTOMATED, ELEMENT-SPECIFIC DETECTOR FOR HIGH-PRESSURE LIQUID CHROMATOGRAPHY - SEPARATION OF ARSENOBETAINE, ARSENOCHOLINE AND ARSENITE-ARSENATE [J].
STOCKTON, RA ;
IRGOLIC, KJ .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1979, 6 (04) :313-319
[24]   BACKGROUND SPECTRAL FEATURES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
TAN, SH ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1986, 40 (04) :445-460
[25]   SIMPLE AND RAPID PROCEDURE FOR THE DETERMINATION OF LEAD IN WHOLE-BLOOD BY USE OF A SLOTTED TUBE AND DISCRETE NEBULIZATION FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
TAYLOR, A ;
BROWN, AA .
ANALYST, 1983, 108 (1290) :1159-1161
[26]   INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION FOR MULTIELEMENT FLOW-INJECTION ANALYSIS AND ELEMENTAL SPECIATION BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
THOMPSON, JJ ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1986, 58 (12) :2541-2548
[27]   ION-EXCHANGE AS A SEPARATIONS METHOD .1. THE SEPARATION OF FISSION-PRODUCED RADIOISOTOPES, INCLUDING INDIVIDUAL RARE EARTHS, BY COMPLEXING ELUTION FROM AMBERLITE RESIN [J].
TOMPKINS, ER ;
KHYM, JX ;
COHN, WE .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1947, 69 (11) :2769-2777
[28]   INTERFACED DC ARGON-PLASMA EMISSION SPECTROSCOPIC DETECTION FOR HIGH-PRESSURE LIQUID-CHROMATOGRAPHY OF METAL-COMPOUNDS [J].
UDEN, PC ;
QUIMBY, BD ;
BARNES, RM ;
ELLIOTT, WG .
ANALYTICA CHIMICA ACTA, 1978, 101 (01) :99-109
[29]   SPRAY CHAMBER PLACEMENT AND MOBILE PHASE FLOW-RATE EFFECTS IN LIQUID-CHROMATOGRAPHY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
WHALEY, BS ;
SNABLE, KR ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1982, 54 (02) :162-165
[30]  
YAN N, 1990, IN PRESS SCI TOTAL E