共 4 条
MONITORING LEAKS FROM STORAGE PONDS USING RESISTIVITY METHODS
被引:30
作者:
VAN, GP
[1
]
PARK, SK
[1
]
HAMILTON, P
[1
]
机构:
[1] SO CALIF EDISON CO,ROSEMEADE,CA 91770
来源:
关键词:
D O I:
10.1190/1.1443147
中图分类号:
P3 [地球物理学];
P59 [地球化学];
学科分类号:
0708 ;
070902 ;
摘要:
We installed a resistivity monitoring system in 1988 beneath and around a large evaporation pond at the Mohave Generating Station in Laughlin, Nevada. Changes between repeated measurements on a sparse, permanent grid of electrodes are used to detect leaks. The pond covers 222 585 m2 and would require over 100 traverses with Parra's method in order to adequately sample the pond. This is not practical for such a large pond. The method described here also detects brine in the sediments, not a hole in an insulating liner, and thus the size of the leak and the extent of the contamination may also be estimated. -Authors
引用
收藏
页码:1267 / 1270
页数:4
相关论文