Combined Orbital Floor and Medial Wall Fractures Involving the Inferomedial Strut: Repair Technique and Case Series Using Preshaped Porous Polyethylene/Titanium Implants

被引:28
作者
Cho, Raymond I. [1 ]
Davies, Brett W. [2 ]
机构
[1] San Antonio Mil Med Ctr, Oculoplast & Orbital Surg Serv, San Antonio, TX 78234 USA
[2] Wilford Hall Ambulatory Surg Ctr, Dept Ophthalmol, San Antonio, TX 78236 USA
关键词
orbital fracture; orbital floor; medial wall; inferomedial strut; porous polyethylene; titanium;
D O I
10.1055/s-0033-1343785
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Combined orbital floor and medial wall fractures can be technically challenging to repair, particularly when the inferomedial strut is involved. A surgical repair technique is described utilizing a single preshaped porous polyethylene/titanium implant to span both defects. Methods Retrospective interventional case series. Results Fracture repair was performed on 17 orbits (16 patients) between October 2009 and February 2012. Subsequent surgical revision was required in three cases (18%). Visual acuity was stable or improved in all cases. Of 7 patients with preoperative diplopia, 5 improved and 2 remained stable postoperatively, and there were no cases of new or worsened diplopia following surgery. Postoperative asymmetry in Hertel exophthalmometry averaged 1.0 mm (range 0 to 2 mm). Preoperatively, average orbital volume was 122.7% compared with control (range 109 to 147%, standard deviation [SD] 9.6), which improved to 100.3% postoperatively (range 92 to 110%, SD 5.7). The average decrease in orbital volume was 22.5% (range 10 to 54%, SD 11.4, p < 0.001). Conclusions With careful preoperative planning and meticulous surgical technique, combined orbital floor and medial wall fractures involving the inferomedial strut can be successfully repaired with a preshaped porous polyethylene/ titanium implant through a transconjunctival/transcaruncular approach with inferior oblique disinsertion.
引用
收藏
页码:161 / 169
页数:9
相关论文
共 33 条
[1]  
APPLING WD, 1993, ARCH OTOLARYNGOL, V119, P1000
[2]  
Burnstine Michael A, 2003, Curr Opin Ophthalmol, V14, P236, DOI 10.1097/00055735-200310000-00002
[3]   Porous polyethylene channel implants: A modified porous polyethylene sheet implant designed for repairs of large and complex orbital wall fractures [J].
Choi, JC ;
Fleming, JC ;
Aitken, PA ;
Shore, JW .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 15 (01) :56-66
[4]  
Dortzbach R K, 1985, Ophthalmic Plast Reconstr Surg, V1, P149, DOI 10.1097/00002341-198501020-00014
[5]  
DUTTON JJ, 1991, SURV OPHTHALMOL, V35, P279
[6]   Use of porous polyethylene with embedded titanium in orbital reconstruction: A review of 106 patients [J].
Garibaldi, Daniel C. ;
Nicholas, T. Iliff ;
Grant, Michael P. ;
Merbs, Shannath L. .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 23 (06) :439-444
[7]   THE MEDIAL ORBITAL STRUT IN THE PREVENTION OF POSTDECOMPRESSION DYSTOPIA IN DYSTHYROID OPHTHALMOPATHY [J].
GOLDBERG, RA ;
SHORR, N ;
COHEN, MS .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 8 (01) :32-34
[8]   The transcaruncular approach to the medial orbital wall [J].
Graham, SM ;
Thomas, RD ;
Carter, KD ;
Nerad, JA .
LARYNGOSCOPE, 2002, 112 (06) :986-989
[9]   Orbital blow-out fractures: surgical timing and technique [J].
Harris, G. J. .
EYE, 2006, 20 (10) :1207-1212
[10]  
Holck DEE, 2005, INTERNAL ORBITAL WAL