THE SENSITIVITY OF DROSOPHILA LARVAE TO CONTINUOUS-WAVE ULTRASOUND

被引:3
|
作者
CHILD, SZ [1 ]
RAEMAN, CH [1 ]
WALTERS, E [1 ]
CARSTENSEN, EL [1 ]
机构
[1] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1992年 / 18卷 / 08期
关键词
CW ULTRASOUND; LARVAE; GAS BODY ACTIVATION; CAVITATION;
D O I
10.1016/0301-5629(92)90123-R
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The threshold for killing of freshly hatched Drosophila larvae exposed to continuous-wave (CW) ultrasound shows a minimum at approximately 0.3 MHz. This suggests that the stiffness of the material surrounding the gas bodies in the organism is comparable to water. From this, it is apparent that the gas bodies in three-day-old larvae that we have used in earlier studies are far larger than resonance size at the frequencies (1-5 MHz) used. Yet, these larvae were killed by short exposures to low-temporal-average-intensity pulsed ultrasound with peak intensities of the order of 10 W/cm2. Hence, it appears that "large" bubbles cannot be ignored in considerations of the biological effects of pulsed ultrasound and lithotripsy.
引用
收藏
页码:725 / 728
页数:4
相关论文
共 50 条
  • [31] Continuous-wave photoacoustic microscopy
    Maslov, Konstantin
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2007, 2007, 6437
  • [32] A CONTINUOUS-WAVE CHEMICAL LASER
    SUART, RD
    KIMBELL, GH
    ARNOLD, SJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (06): : 808 - &
  • [33] Continuous-wave cavity ringdown for high-sensitivity polarimetry and magnetometry measurements
    Tran, Dang-Bao-An
    Edwards, Evan G. P.
    Tew, David P.
    Peverall, Robert
    Ritchie, Grant A. D.
    JOURNAL OF CHEMICAL PHYSICS, 2024, 160 (05):
  • [34] Continuous-wave submillimeter-wave gyrotrons
    Han, Seong-Tae
    Griffin, Robert G.
    Hu, Kan-Nian
    Joo, Chan-Gyu
    Joye, Colin D.
    Mastovsky, Ivan
    Shapiro, Michael A.
    Sirigiri, Jagadishwar R.
    Temkin, Richard J.
    Torrezan, Antonio C.
    Woskov, Paul P.
    TERAHERTZ PHYSICS, DEVICES, AND SYSTEMS, 2006, 6373
  • [35] LUNG LESIONS INDUCED BY CONTINUOUS-WAVE AND PULSED-WAVE (DIAGNOSTIC) ULTRASOUND IN MICE, RABBITS, AND PIGS
    ZACHARY, JF
    OBRIEN, WD
    VETERINARY PATHOLOGY, 1995, 32 (01) : 43 - 54
  • [36] SONOLUMINESCENCE IN WATER AND AGAR GELS DURING IRRADIATION WITH 0.75 MHZ CONTINUOUS-WAVE ULTRASOUND
    DANIELS, S
    PRICE, DJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (03): : 297 - 308
  • [37] Anisotropic diffusion technique to eliminate speckle noise in continuous-wave Doppler ultrasound spectrogram
    Bharadwaj S.
    Journal of Medical Engineering and Technology, 2021, 45 (01): : 35 - 40
  • [38] SPECTRUM ANALYSIS OF CONTINUOUS-WAVE DOPPLER ULTRASOUND SIGNALS OF THE EXTRACRANIAL CAROTID-ARTERY
    HENNERICI, M
    DAFFERTSHOFER, M
    ESSER, G
    AULICH, A
    VASA-JOURNAL OF VASCULAR DISEASES, 1985, 14 (02): : 131 - 138
  • [39] USE OF CONTINUOUS-WAVE DOPPLER ULTRASOUND TO EVALUATE AND MANAGE PRIMARY PULMONARY-HYPERTENSION
    HECHT, SR
    BERGER, M
    BERDOFF, RL
    VANTOSH, A
    STIMOLA, JM
    CHEST, 1986, 90 (05) : 781 - 783
  • [40] Comparisons of Continuous-wave Doppler Ultrasound Monitor and Echocardiography in Cardiac Postoperative Pediatric Patients
    Shostak, Eran
    Nahum, Elchanan
    Shochat, Tzippy
    Manor, Orit
    Dagan, Ovadia
    Schiller, Ofer
    JOURNAL OF INTENSIVE CARE MEDICINE, 2022, : 1634 - 1640