DESIGN AND DEVELOPMENT OF ULTRATHIN-WALLED, NONKINKING ENDOTRACHEAL-TUBES OF A NEW NO-PRESSURE LARYNGEAL SEAL DESIGN - A PRELIMINARY-REPORT

被引:14
作者
KOLOBOW, T
TSUNO, K
ROSSI, N
APRIGLIANO, M
机构
[1] National Institutes of Health, Building 10, Bethesda, MD 20892
关键词
EQUIPMENT; CUFFS ENDOTRACHEAL TUBES;
D O I
10.1097/00000542-199410000-00031
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Endotracheal tubes (ETTs) of conventional design and manufacture greatly increase the air-flow resistance of the upper airways. This increase in upper-airway resistance can lead to a significant increase in the work of breathing and may necessitate the use of assisted mechanical ventilation. Current ETTs are relatively stiff and contribute greatly to patient discomfort. The inflatable cuffs now mounted onto the ETTs function well in short-term use but impart significant morbidity when used over longer periods. These issues were addressed by the designing of a low-resistance ETT. Methods: Using new techniques, we developed ultrathin-walled, wire reinforced ETTs of conventional configuration and ETTs the oropharyngeal-section diameter of which was a few millimeters larger than the diameter of the tracheal section. The wall thickness was a constant 0.20 mm. The wire reinforcement was stainless steel flat wire or superelastic nickel-titanium alloy. The superelastic nickel-titanium alloy reinforcement made those ETTs crush-proof; after forceful manual compression, recovery was complete. To obtain a seal with the upper airways, we first shaped a short section of the oropharyngeal section of the ETT from round to oval (or egg-shaped) to conform better to the larynx. We then attached to this segment numerous soft, pliable, 0.025-0.075-mm-thick rings of polyurethane to occlude voids for potential air leaks from within the larynx. Results: In vitro pressure-flow studies showed a decrease by as much as four- or fivefold in air-flow resistance in the adult ETT range, effectively increasing the internal diameter by 2.3-3.7 mm, compared with conventional ETTs of the same outside diameter. In vivo studies for 24 h in sheep showed no air leaks at airway pressures to 30 cmH(2)O and minimal leak at greater pressures. The gross appearance of the trachea was normal. Conclusions: Although the new tubes appear to offer advantages to those currently used, testing in humans is required to assess the clinical utility of the tube-cuff design.
引用
收藏
页码:1061 / 1067
页数:7
相关论文
共 10 条
[1]  
ALTMAN PL, 1971, BIOL HDB RESPIRATION, P99
[2]  
BISHOP MJ, 1984, ANESTH ANALG, V63, P335
[3]  
BOLDER PM, 1986, ANESTH ANALG, V65, P853
[4]   INJURIES TO NEONATAL LARYNX FROM LONG-TERM ENDOTRACHEAL-TUBE INTUBATION AND SUGGESTED TUBE MODIFICATION FOR PREVENTION [J].
HENGERER, AS ;
STROME, M ;
JAFFE, BF .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1975, 84 (06) :764-770
[5]  
Magill I W, 1928, Proc R Soc Med, V22, P83
[6]  
MILLER D R, 1970, Annals of Surgery, V171, P283, DOI 10.1097/00000658-197002000-00018
[7]  
Steen JA, 1988, PROBLEMS ANESTHESIA, V2, P211
[8]  
TRENDELENBURG F, 1980, BIOMATERIALS, V1, P41
[9]   DEVELOPMENT OF THE PVC ENDOTRACHEAL-TUBE [J].
WATSON, WF .
BIOMATERIALS, 1980, 1 (01) :41-46
[10]  
WEYMULLER EA, 1988, PROBLEMS ANESTHESIA, V2, P235