THE EFFECT OF ANESTHESIA ON THE BONE BLOOD-FLOW OF THE RABBIT

被引:12
作者
DAVIS, TRC [1 ]
HOLLOWAY, I [1 ]
POOLEY, J [1 ]
机构
[1] ROYAL VICTORIA INFIRM,DEPT MED PHYS,NEWCASTLE TYNE NE1 4LP,TYNE & WEAR,ENGLAND
关键词
Anaesthesia; Bone blood flow; Microspheres;
D O I
10.1002/jor.1100080403
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The effect of anaesthesia on the rate of bone blood flow in the rabbit was studied. Two estimates of bone blood flow were performed, using 15 μm radioactively labelled microspheres, in three groups of rabbits. The first group was anaesthetised and the interval between the two estimates was 5 min. The second group was also anaesthetised but the interval between estimates was 60 min. The third group of rabbits was conscious and the interval between the two estimates was 4 h. In the first group, small uniform falls in whole bone blood flow were observed (mean change = −5%). In the second group, larger and less predictable reductions were observed (mean change = −24%). In the third group (conscious), little change was observed in whole bone blood flow during the 4‐h experiment (mean change = + 7%). It is concluded that substantial falls can occur in bone blood flow in the rabbit during a 1‐h anaesthetic. If bone blood flow is to be monitored under anaesthesia, then the effect of the anaesthetic on bone blood flow must be accurately defined. In conscious rabbits, estimates of whole bone blood flow performed at an interval of 4 h under control conditions will give reproducable results. Copyright © 1990 Orthopaedic Research Society
引用
收藏
页码:479 / 484
页数:6
相关论文
共 23 条
  • [1] SIMPLE RADIOACTIVE MICROSPHERE METHOD FOR MEASURING REGIONAL FLOW AND CARDIAC-OUTPUT
    BARTRUM, RJ
    BERKOWITZ, DM
    HOLLENBERG, NK
    [J]. INVESTIGATIVE RADIOLOGY, 1974, 9 (03) : 126 - 132
  • [2] PARATHYROID-HORMONE EFFECTS ON SKELETAL EXCHANGEABLE CALCIUM AND BONE BLOOD-FLOW
    BRINDLEY, GW
    WILLIAMS, EA
    BRONK, JT
    MEADOWS, TH
    MONTGOMERY, RJ
    SMITH, SR
    KELLY, PJ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (01): : H94 - H100
  • [3] BROOKES M, 1970, J ANAT, V106, P557
  • [4] BROOKES M, 1987, BONE, V4, P33
  • [5] SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES
    BUCKBERG, GD
    LUCK, JC
    PAYNE, DB
    HOFFMAN, JIE
    ARCHIE, JP
    FIXLER, DE
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) : 598 - &
  • [6] BUNGER C, 1985, ACTA ORTHOP SCAND, V56, P169
  • [7] STUDY OF BLOOD FLOW THROUGH BONE MARROW BY A METHOD OF VENOUS EFFLUENT COLLECTION
    CUMMING, JD
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1962, 162 (01): : 13 - &
  • [8] GREEN CJ, 1979, ANIM ANAESTH, P131
  • [9] NEUROHUMORAL REGULATION OF BLOOD-FLOW TO BONES AND MARROW
    GROSS, PM
    HEISTAD, DD
    MARCUS, ML
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (04): : H440 - H448
  • [10] BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES
    HEYMANN, MA
    PAYNE, BD
    HOFFMAN, JIE
    RUDOLPH, AM
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) : 55 - 79