LIGHT AND TRANSMISSION ELECTRON-MICROSCOPY OF THE INTACT INTERFACES BETWEEN NON-SUBMERGED TITANIUM-COATED EPOXY-RESIN IMPLANTS AND BONE OR GINGIVA

被引:126
作者
LISTGARTEN, MA
BUSER, D
STEINEMANN, SG
DONATH, K
LANG, NP
WEBER, HP
机构
[1] HARVARD UNIV,SCH DENT MED,BOSTON,MA 02115
[2] UNIV LAUSANNE,DEPT EXPTL PHYS,CH-1000 LAUSANNE 17,SWITZERLAND
[3] UNIV HAMBURG,INST PATHOL,W-2000 HAMBURG 13,GERMANY
关键词
D O I
10.1177/00220345920710020401
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This experiment was aimed at studying the intact tissue/implant interface of non-submerged dental implants with a titanium surface. Epoxy-resin replicas were fabricated from 3.05 x 8 mm cylindrical titanium implants with a plasma-sprayed apical portion and a smooth coronal collar. The replicas were coated with a 90-120-nm-thick layer of pure titanium and autoclaved. The coated replicas were inserted as non-submerged endosseous implants in the edentulous premolar region of dog mandibles and allowed to heal for three months. Jaw sections containing the implants were processed for light and electron microscopic study of the intact tissue/implant interface with and without prior demineralization. Gingival connective tissue fibers were closely adapted to the titanium layer, in an orientation more or less parallel to the implant surface. There was no evidence of any fiber insertions into the surface irregularities of the smooth or rough titanium surface. Undemineralized bone was intimately adapted to the titanium surface without any intervening space. In demineralized sections, the collagen fibers of the bone matrix tended to be somewhat thinner and occasionally less densely packed in the vicinity of the implant surface. However, they extended all the way to the titanium surface, without any intervening fibril-free layer.
引用
收藏
页码:364 / 371
页数:8
相关论文
共 42 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] INTERFACE ANALYSIS OF TITANIUM AND ZIRCONIUM BONE IMPLANTS
    ALBREKTSSON, T
    HANSSON, HA
    IVARSSON, B
    [J]. BIOMATERIALS, 1985, 6 (02) : 97 - 101
  • [3] BONE-METAL INTERFACE IN OSSEOINTEGRATION
    ALBREKTSSON, T
    JACOBSSON, M
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (05) : 597 - 607
  • [4] OSSEOINTEGRATED ORAL IMPLANTS - A SWEDISH MULTICENTER STUDY OF 8139 CONSECUTIVELY INSERTED NOBELPHARMA IMPLANTS
    ALBREKTSSON, T
    DAHL, E
    ENBOM, L
    ENGEVALL, S
    ENGQUIST, B
    ERIKSSON, AR
    FELDMANN, G
    FREIBERG, N
    GLANTZ, PO
    KJELLMAN, O
    KRISTERSSON, L
    KVINT, S
    KONDELL, PA
    PALMQUIST, J
    WERNDAHL, L
    ASTRAND, P
    [J]. JOURNAL OF PERIODONTOLOGY, 1988, 59 (05) : 287 - 296
  • [5] AN ULTRASTRUCTURAL CHARACTERIZATION OF THE INTERFACE BETWEEN BONE AND SPUTTERED TITANIUM OR STAINLESS-STEEL SURFACES
    ALBREKTSSON, T
    HANSSON, HA
    [J]. BIOMATERIALS, 1986, 7 (03) : 201 - 205
  • [6] THE INTERFACE ZONE OF INORGANIC IMPLANTS INVIVO - TITANIUM IMPLANTS IN BONE
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    KASEMO, B
    LARSSON, K
    LUNDSTROM, I
    MCQUEEN, DH
    SKALAK, R
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1983, 11 (01) : 1 - 27
  • [7] BABBUSH CA, 1986, DENT CLIN N AM, V30, P117
  • [8] BABBUSH CA, 1986, DENT CLIN N AM, V30, P133
  • [9] BRANEMARK PI, 1977, SCAND J PLAST RE S16, V2
  • [10] INFLUENCE OF FUNCTIONAL USE OF ENDOSSEOUS DENTAL IMPLANTS ON THE TISSUE-IMPLANT INTERFACE .1. HISTOLOGICAL ASPECTS
    BRUNSKI, JB
    MOCCIA, AF
    POLLACK, SR
    KOROSTOFF, E
    TRACHTENBERG, DI
    [J]. JOURNAL OF DENTAL RESEARCH, 1979, 58 (10) : 1953 - 1969