ROLE OF THE CAPSULO-LIGAMENTOUS STRUCTURES IN ROTATION AND COMBINED FLEXION-ROTATION OF THE LUMBAR SPINE

被引:20
作者
GUNZBURG, R
HUTTON, WC
CRANE, G
FRASER, RD
机构
[1] Department of Orthopaedic Surgery and Trauma, Brugmann University Hospital, Free University of Brussels
[2] Department of Orthopaedic Research, Emory University, Atlanta, GA
[3] School of Information Science and Technology, The Flinders University, Adelaide, SA
[4] Department of Orthopaedic Surgery and Trauma, Royal Adelaide Hospital, Adelaide, SA
来源
JOURNAL OF SPINAL DISORDERS | 1992年 / 5卷 / 01期
关键词
LUMBAR SPINE; FLEXION; ROTATION; POSTERIOR CAPSULO-LIGAMENTOUS STRUCTURES;
D O I
10.1097/00002517-199203000-00001
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We carried out experiments on whole cadaveric lumbar spines in order to determine the role that each of the capsulo-ligamentous structures play in axial rotation in the neutral position and in the flexed position. Eight specimens were first tested intact, then after division of all the apophyseal joint capsules between L1 and the sacrum. Another five specimens were also first tested intact, then after division of the supra- and interspinous ligaments and yellow ligament, and finally after cutting the posterior longitudinal ligament and posterior annulus at each level as well. The results show that there is considerable variation in the axial rotation of the lumbar vertebrae within the same spine and across different spines. The apophyseal joint capsules limit rotation both in neutral and flexed positions. In flexion, the amplitude of rotation in the lumbar spine is reduced. Of the capsulo-ligamentous structures, it is the posterior annulus and the posterior longitudinal ligament that seem to play the more important role in limiting axial rotation while the spine is flexed.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 32 条
  • [1] AXIAL ROTATION OF THE LUMBAR SPINE AND THE EFFECT OF FLEXION - AN INVITRO AND INVIVO BIOMECHANICAL STUDY
    GUNZBURG, R
    HUTTON, W
    FRASER, R
    SPINE, 1991, 16 (01) : 22 - 28
  • [2] Optimised loads for the simulation of axial rotation in the lumbar spine
    Dreischarf, Marcel
    Rohlmann, Antonius
    Bergmann, Georg
    Zander, Thomas
    JOURNAL OF BIOMECHANICS, 2011, 44 (12) : 2323 - 2327
  • [3] Instantaneous center of rotation behavior of the lumbar spine with ligament failure
    Alapan, Yunus
    Demir, Cihan
    Kaner, Tuncay
    Guclu, Rahmi
    Inceoglu, Serkan
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 18 (06) : 617 - 626
  • [4] Flexion-Rotation Trunk Test to Assess Abdominal Muscle Endurance: Reliability, Learning Effect, and Sex Differences
    Brotons-Gil, Evaristo
    Garcia-Vaquero, Maria P.
    Peco-Gonzalez, Noelia
    Vera-Garcia, Francisco J.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2013, 27 (06) : 1602 - 1608
  • [5] Trajectory of instantaneous axis of rotation in fixed lumbar spine with instrumentation
    Masataka Inoue
    Tetsutaro Mizuno
    Toshihiko Sakakibara
    Takaya Kato
    Takamasa Yoshikawa
    Tadashi Inaba
    Yuichi Kasai
    Journal of Orthopaedic Surgery and Research, 12
  • [6] Application of image registration to measurement of intervertebral rotation in the lumbar spine
    Rogers, BP
    Haughton, VM
    Arfanakis, K
    Meyerand, ME
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) : 1072 - 1075
  • [7] Trajectory of instantaneous axis of rotation in fixed lumbar spine with instrumentation
    Inoue, Masataka
    Mizuno, Tetsutaro
    Sakakibara, Toshihiko
    Kato, Takaya
    Yoshikawa, Takamasa
    Inaba, Tadashi
    Kasai, Yuichi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [8] Influence of posture on the range of axial rotation and coupled lateral flexion of the thoracic spine
    Edmondston, Stephen J.
    Aggerholm, Mathew
    Elfving, Suzanne
    Flores, Nell
    Ng, Christopher
    Smith, Richard
    Netto, Kevin
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2007, 30 (03) : 193 - 199
  • [9] EFFECTS OF POSTERIOR INSTRUMENTATION ON AXIAL ROTATION OF THE LUMBAR SPINE - AN IN-VITRO BIOMECHANICAL STUDY
    GUNZBURG, R
    HUTTIN, WC
    JOURNAL OF SPINAL DISORDERS, 1995, 8 (02): : 103 - 110
  • [10] Assessment of movement distribution in the lumbar spine using the instantaneous axis of rotation
    Park, Kiwon
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (12) : 5063 - 5067