LINEAR STAPLING DEVICE IN PARTIAL RESECTION OF ABDOMINAL PARENCHYMATOUS ORGANS

被引:0
|
作者
SCHEIN, M
BANIEL, J
DEGIDIO, A
HASHMONAI, M
机构
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
The use of the linear stapling device (LSD) is well-established in hollow-organ gastro-intestinal surgery. Its use in operations performed on parenchymatous viscera is less common. We present our experiences with the LSD in partial resection of the spleen (2 cases), pancreas (5 cases), liver (2 cases) and kidney (2 cases). To the best of our knowledge the use of the LSD for partial nephrectomy and resectional debridement of the liver has not been previously described. We suggest that LSDs are useful aids in the resection of parenchymatous organs, and allow rapid resection if applied to healthy tissues and in regions with an intact capsule.
引用
收藏
页码:47 / 48
页数:2
相关论文
共 50 条
  • [31] CUTANEOUS PERIANAL RECURRENCE OF CANCER AFTER ANTERIOR RESECTION USING THE EEA STAPLING DEVICE
    REED, MWR
    STODDARD, CJ
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1992, 74 (04) : 301 - 302
  • [32] Extracorporal resection of the rectum in the treatment of complete rectal prolapse using a circular stapling device
    Schütz, G
    DIGESTIVE SURGERY, 2001, 18 (04) : 274 - 277
  • [33] Biomechanical Evaluation of a Novel Subcuticular Skin Stapling Device for Use in Equine Abdominal Surgeries
    Biedrzycki, Adam
    Markel, Mark D.
    Brounts, Sabrina H.
    VETERINARY SURGERY, 2015, 44 (02) : 231 - 235
  • [34] Intra-abdominal side-to-end stapling technique for anterior resection of rectal cancer
    Yamamura, T
    Akaishi, O
    Tsukikawa, S
    JOURNAL OF SURGICAL ONCOLOGY, 1997, 66 (02) : 139 - 140
  • [35] SYMMETRICAL DOUBLE SPLEEN IN PARTIAL SITUS INVERSUS OF ABDOMINAL ORGANS
    GURICH, HG
    ACTA HEPATO-SPLENOLOGICA, 1968, 15 (01): : 43 - &
  • [36] REPAIR OF DEFECTS AFTER PARTIAL RESECTION OF THE ABDOMINAL WALL
    HERSHEY, FB
    BUTCHER, HR
    AMERICAN JOURNAL OF SURGERY, 1964, 107 (04): : 586 - 590
  • [37] Effects of the time interval between clamping and linear stapling for resection of porcine small intestine
    Morita, K.
    Maeda, N.
    Kawaoka, T.
    Hiraki, S.
    Kudo, A.
    Fukuda, S.
    Oka, M.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (03): : 750 - 756
  • [38] Effects of the time interval between clamping and linear stapling for resection of porcine small intestine
    K. Morita
    N. Maeda
    T. Kawaoka
    S. Hiraki
    A. Kudo
    S. Fukuda
    M. Oka
    Surgical Endoscopy, 2008, 22 : 750 - 756
  • [39] Laparoscopic partial cystectomy with endo-GIA stapling device in bladder diverticular carcinoma
    Wang, Chun-Kai
    Chueh, Shih-Chieh
    JOURNAL OF ENDOUROLOGY, 2007, 21 (07) : 772 - 775
  • [40] Use of linear radiofrequency device in liver resection
    Stojanovic, Miroslav
    Radojkovic, Milan
    Stanojevic, Goran
    VOJNOSANITETSKI PREGLED, 2010, 67 (11) : 910 - 915