Accuracy of a real-time continuous glucose monitoring system in children with septic shock: A pilot study

被引:9
|
作者
Prabhudesai, Sumant [1 ]
Kanjani, Amruta [2 ]
Bhagat, Isha [3 ]
Ravikumar, Karnam G. [4 ]
Ramachandran, Bala [4 ]
机构
[1] Royal Manchester Childrens Hosp, Oxford Rd, Manchester M13 9WL, Lancs, England
[2] Columbia Asia Hosp, Ahmedebad, Gujrat, India
[3] PD Hinduja Natl Hosp & Med Res Ctr, Bombay, Maharashtra, India
[4] Kanchi Kamakoti CHILDS Trust Hosp, Madras, Tamil Nadu, India
关键词
Children; continuous glucose monitoring system; septic shock;
D O I
10.4103/0972-5229.169331
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The aim of this prospective, observational study was to determine the accuracy of a real-time continuous glucose monitoring system (CGMS) in children with septic shock. Subjects and Methods: Children aged 30 days to 18 years admitted to the Pediatric Intensive Care Unit with septic shock were included. A real-time CGMS sensor was used to obtain interstitial glucose readings. CGMS readings were compared statistically with simultaneous laboratory blood glucose (BG). Results: Nineteen children were included, and 235 pairs of BG-CGMS readings were obtained. BG and CGMS had a correlation coefficient of 0.61 (P < 0.001) and a median relative absolute difference of 17.29%. On Clarke's error grid analysis, 222 ( 94.5%) readings were in the clinically acceptable zones (A and B). When BG was < 70, 70-180, and > 180 mg/dL, 44%, 100%, and 76.9% readings were in zones A and B, respectively (P < 0.001). The accuracy of CGMS was not affected by the presence of edema, acidosis, vasopressors, steroids, or renal replacement therapy. On receiver operating characteristics curve analysis, a CGMS reading < 97 mg/dL predicted hypoglycemia (sensitivity 85.2%, specificity 75%, area under the curve [AUC] =0.85). A reading > 141 mg/dL predicted hyperglycemia (sensitivity 84.6%, specificity 89.6%, AUC =0.87). Conclusion: CGMS provides a fairly, accurate estimate of BG in children with septic shock. It is unaffected by a variety of clinical variables. The accuracy over extremes of blood sugar may be a concern. We recommend larger studies to evaluate its use for the early detection of hypoglycemia and hyperglycemia.
引用
收藏
页码:642 / 647
页数:6
相关论文
共 50 条
  • [1] Multicenter Evaluation Study Comparing a New Factory-Calibrated Real-Time Continuous Glucose Monitoring System to Existing Flash Glucose Monitoring System
    Ji, Linong
    Guo, Lixin
    Zhang, Junqing
    Li, Yufeng
    Chen, Zhiyan
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (01): : 208 - 213
  • [2] Educating Families on Real Time Continuous Glucose Monitoring The DirecNet Navigator Pilot Study Experience
    Messer, Laurel
    Ruedy, Katrina
    Xing, Dongyuan
    Coffey, Julie
    Englert, Kimberly
    Caswell, Kimberly
    Ives, Brett
    DIABETES EDUCATOR, 2009, 35 (01) : 124 - 135
  • [3] Real-Time Continuous Glucose Monitoring Shows High Accuracy within 6 Hours after Sensor Calibration: A Prospective Study
    Yue, Xiao-Yan
    Zheng, Yi
    Cai, Ye-Hua
    Yin, Ning-Ning
    Zhou, Jian-Xin
    PLOS ONE, 2013, 8 (03):
  • [4] Real-Time Sharing and Following of Continuous Glucose Monitoring Data in Youth
    John B. Welsh
    Mark Derdzinski
    Andrew Scott Parker
    Sarah Puhr
    Annika Jimenez
    Tomas Walker
    Diabetes Therapy, 2019, 10 : 751 - 755
  • [5] Real-Time Continuous Glucose Monitoring Systems in the Classroom/School Environment
    Benassi, Kari
    Drobny, Jessica
    Aye, Tandy
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (05) : 409 - 412
  • [6] Real-Time Sharing and Following of Continuous Glucose Monitoring Data in Youth
    Welsh, John B.
    Derdzinski, Mark
    Parker, Andrew Scott
    Puhr, Sarah
    Jimenez, Annika
    Walker, Tomas
    DIABETES THERAPY, 2019, 10 (02) : 751 - 755
  • [7] Septic Shock Prediction by Real Time Monitoring of Heart Rate Variability
    Yokota, Y.
    Kawamura, Y.
    Matsumaru, N.
    Shirai, K.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 195 - +
  • [8] Multimodal Monitoring for Hemodynamic Categorization and Management of Pediatric Septic Shock: A Pilot Observational Study
    Ranjit, Suchitra
    Aram, Gnanam
    Kissoon, Niranjan
    Ali, Mhd Kashif
    Natraj, Rajeshwari
    Shresti, Sharad
    Jayakumar, Indira
    Gandhi, Deepika
    PEDIATRIC CRITICAL CARE MEDICINE, 2014, 15 (01) : E17 - E26
  • [9] Real-time continuous glucose monitoring versus internet-based blood glucose monitoring in adults with type 2 diabetes: A study of treatment satisfaction
    Tang, Tricia S.
    Digby, Erica M.
    Wright, Anthony M.
    Chan, Jeremy H. M.
    Mazanderani, Adel B.
    Ross, Stuart A.
    Tildesley, Hamish G.
    Lee, Augustine M.
    White, Adam S.
    Tildesley, Hugh D.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2014, 106 (03) : 481 - 486
  • [10] Real-Time Monitoring of School Absenteeism to Enhance Disease Surveillance: A Pilot Study of a Mobile Electronic Reporting System
    Lawpoolsri, Saranath
    Khamsiriwatchara, Amnat
    Liulark, Wongwat
    Taweeseneepitch, Komchaluch
    Sangvichean, Aumnuyphan
    Thongprarong, Wiraporn
    Kaewkungwal, Jaranit
    Singhasivanon, Pratap
    JMIR MHEALTH AND UHEALTH, 2014, 2 (02):