Long-term Follow-up Angiography of Intracranial Aneurysms Treated with Cook Detachable Coil System

被引:0
|
作者
Pardo, M. I. [1 ]
Pumar, J. M. [2 ]
Abal, D. [2 ]
Garcia-Allut, A. [2 ]
Blanco, M. [2 ]
Vazquez, F. [2 ]
机构
[1] Prov Hosp, Dept Gynecol, Loureiro Crespo S-N, Pontevedra 36001, Spain
[2] Univ Hosp, Santiago De Compostela, Spain
关键词
embolization; cerebral aneurysms; coiling; endovascular treatment;
D O I
10.1177/197140090802100517
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
The long-term outcome of detachable coil embolization of cerebral aneurysms is still unknown. The purpose of this study was to evaluate the stability of the anatomic occlusion of aneurysms treated with the Cook detachable coil system and assess the rate of recanalization and recurrence. A study involving 250 patients with 271 ruptured aneurysms treated with the Cook detachable system between January 1997 and September 2003 who subsequently underwent six month, one year and two year follow-up angiography were enrolled in the study. Angiographic findings were reviewed to determine the percentage of aneurysm occlusion. Long-term follow-up angiograms (at two years) demonstrated complete occlusion in 75% of cases, and subtotal occlusion in 25% of cases. Overall morbidity was 7.3%, aneurysm recurrence 3.2%, and aneurysm re-treatment 3.2%. Recurrent subarachnoid hemorrhage occurred in only one patient. Angiographic follow-up demonstrated the stability and durability of treatment with the Cook detachable coil system.
引用
收藏
页码:712 / 716
页数:5
相关论文
共 50 条
  • [41] Treatment of Intracranial Aneurysms Using the Pipeline Flow-Diverter Embolization Device: A Single-Center Experience with Long-Term Follow-Up Results
    Saatci, I.
    Yavuz, K.
    Ozer, C.
    Geyik, S.
    Cekirge, H. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (08) : 1436 - 1446
  • [42] Long-Term Follow-Up Results following Elective Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization Device
    Chiu, A. H. Y.
    Cheung, A. K.
    Wenderoth, J. D.
    De Villiers, L.
    Rice, H.
    Phatouros, C. C.
    Singh, T. P.
    Phillips, T. J.
    McAuliffe, W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (09) : 1728 - 1734
  • [43] Short-term outcome for saccular cerebral aneurysms treated with the Orbit Galaxy Detachable Coil System
    Koltz, Michael T.
    Chalouhi, Nohra
    Tjoumakaris, Stavropoula
    Gonzalez, L. Fernando
    Dumont, Aaron
    Hasan, David
    Rosenwasser, Robert
    Jabbour, Pascal
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (01) : 148 - 152
  • [44] Long-term follow-up in the endovascular treatment of intracranial aneurysms with flow-diverter stents: update of a single-centre experience
    Guzzardi, Giuseppe
    Stanca, Carmelo
    Cerini, Paolo
    Del Sette, Bruno
    Divenuto, Ignazio
    Malatesta, Emanuele
    Carriero, Alessandro
    Stecco, Alessandro
    RADIOLOGIA MEDICA, 2018, 123 (06): : 449 - 455
  • [45] Management and long-term follow-up of basilar trunk artery aneurysms: a single center experience
    Gu, Feng
    Li, Jiaxuan
    Tian, Zhichao
    Meng, Jiahao
    Tao, Xinyu
    Li, Bohan
    You, Wanchun
    Wang, Zhong
    NEUROSURGICAL REVIEW, 2025, 48 (01)
  • [46] Long-term follow-up of the pCONus device for the treatment of wide-neck bifurcation aneurysms
    Guenego, Adrien
    Mine, Benjamin
    Bonnet, Thomas
    Elens, Stephanie
    Vazquez Suarez, Juan
    Jodaitis, Lise
    Ligot, Noemie
    Naeije, Gilles
    Lubicz, Boris
    INTERVENTIONAL NEURORADIOLOGY, 2022, 28 (04) : 455 - 462
  • [47] Long-term angiographic follow-up is mandatory after endovascular treatment of aneurysms
    Raymond, J
    Georganos, SA
    Guilbert, F
    Lambert, A
    Lamoureux, J
    Weill, A
    Roy, D
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (06): : 1175 - 1176
  • [48] Long-term follow-up after embolization of pulmonary arteriovenous malformations with detachable silicone balloons
    Andersen, Poul Erik
    Kjeldsen, Anette D.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 31 (03) : 569 - 574
  • [49] Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons
    Poul Erik Andersen
    Anette D. Kjeldsen
    CardioVascular and Interventional Radiology, 2008, 31 : 569 - 574
  • [50] Long-Term Follow-Up after Treatment of Intracranial Aneurysms with the Pipeline Embolization Device: Results from a Single Center
    Deutschmann, H. A.
    Wehrschuetz, M.
    Augustin, M.
    Niederkorn, K.
    Klein, G. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (03) : 481 - 486