ASSESSMENT AND VISUALIZATION OF THE CURVATURE OF THE LEFT-VENTRICLE FROM 3D MEDICAL IMAGES

被引:18
作者
FRIBOULET, D [1 ]
MAGNIN, IE [1 ]
MATHIEU, C [1 ]
POMMERT, A [1 ]
HOEHNE, KH [1 ]
机构
[1] UKE,INST MATH & COMP SCI MED,W-2000 HAMBURG 20,GERMANY
关键词
LEFT VENTRICLE; CURVATURE ESTIMATION; 3D NONRIGID MOTION; 3D IMAGE PROCESSING; 3D VISUALIZATION;
D O I
10.1016/0895-6111(93)90015-F
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We address the problem of using curvature features to assess the three-dimensional (3D) motion of the left ventricle. The adequacy of this approach depends on the actual characteristics of the curvature of the left ventricle and particularly on the spatial and temporal stability of these features. From experimental data, we compute the distribution of the Gaussian curvature over the surface of the left ventricle by using an iterative procedure. The results are visualized in 3D through a voxel-based surface rendering technique. We show that the Gaussian curvature remains stable along the cardiac cycle. This curvature feature could thus provide a reliable basis for further 3D motion analysis of the left ventricle.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [41] 3D Visualization of the Radar Environment
    Qiu, Hang
    Chen, Leiting
    Cai, Hongbin
    MICRO NANO DEVICES, STRUCTURE AND COMPUTING SYSTEMS, 2011, 159 : 327 - 332
  • [42] 3D visualization for software development
    Bonyuet, D
    Ma, M
    Jaffrey, K
    IEEE INTERNATIONAL CONFERENCE ON WEB SERVICES, PROCEEDINGS, 2004, : 708 - 715
  • [43] An autostereoscopic 3D display can improve visualization of 3D models from intracranial MR angiography
    Abildgaard, Andreas
    Witwit, Alaa Kasid
    Karlsen, Jorn Skaarud
    Jacobsen, Eva Astrid
    Tennoe, Bjorn
    Ringstad, Geir
    Due-Tonnessen, Paulina
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (05) : 549 - 554
  • [44] An autostereoscopic 3D display can improve visualization of 3D models from intracranial MR angiography
    Andreas Abildgaard
    Alaa Kasid Witwit
    Jørn Skaarud Karlsen
    Eva Astrid Jacobsen
    Bjørn Tennøe
    Geir Ringstad
    Paulina Due-Tønnessen
    International Journal of Computer Assisted Radiology and Surgery, 2010, 5 : 549 - 554
  • [45] Tomographic PIV in a model of the left ventricle: 3D flow past biological and mechanical heart valves
    Saaid, Hicham
    Voorneveld, Jason
    Schinkel, Christiaan
    Westenberg, Jos
    Gijsen, Frank
    Segers, Patrick
    Verdonck, Pascal
    de Jong, Nico
    Bosch, Johan G.
    Kenjeres, Sasa
    Claessens, Tom
    JOURNAL OF BIOMECHANICS, 2019, 90 (40-49) : 40 - 49
  • [46] Intraventricular vortex flow changes in the infarcted left ventricle: numerical results in an idealised 3D shape
    Domenichini, Federico
    Pedrizzetti, Gianni
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (01) : 95 - 101
  • [47] Recognition and 3D Visualization of Human Body Parts and Bone Areas Using CT Images
    Nguyen, Hai Thanh
    Nguyen, My N. N.
    Nguyen, Bang Anh
    Nguyen, Linh Chi
    Phung, Linh Duong
    APPLIED COMPUTER SYSTEMS, 2023, 28 (01) : 66 - 77
  • [48] 3D Shape Modelling of Left Ventricle : Towards Correlation of Myocardial Scintigraphy data and Coronarography Result
    Abdallah, Ben
    Essabbah, H.
    Bedoui, M. H.
    PROCEEDINGS OF WORLD ACADEMY OF SCIENCE, ENGINEERING AND TECHNOLOGY, VOL 3, 2005, 3 : 48 - 51
  • [49] Investigation of the relationship between age and the angle of aortic insertion on the left ventricle using 3D MRI
    Raphael D Hazel
    Simcha Pollack
    Nathaniel Reichek
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [50] EVALUATION OF REGIONAL LOAD IN ACUTE-ISCHEMIA BY 3-DIMENSIONAL CURVATURES ANALYSIS OF THE LEFT-VENTRICLE
    LESSICK, J
    SIDEMAN, S
    AZHARI, H
    SHAPIRO, E
    WEISS, JL
    BEYAR, R
    ANNALS OF BIOMEDICAL ENGINEERING, 1993, 21 (02) : 147 - 161