ELASTIC AND VISCOELASTIC PROPERTIES OF TRABECULAR BONE - DEPENDENCE ON STRUCTURE

被引:139
作者
PUGH, JW
ROSE, RM
RADIN, EL
机构
[1] HOSP JOINT DIS & MED CTR,DEPT ORTHOPAEDICS,NEW YORK,NY 10035
[2] MIT,DEPT MET & MAT SCI,CAMBRIDGE,MA 02139
[3] HARVARD UNIV,CHILDRENS HOSP,MED CTR,MED SCH,DEPT ORTHOPAED SURG,BOSTON,MA 02115
基金
美国国家科学基金会;
关键词
BIOMECHANICS; -; VISCOELASTOMETERS;
D O I
10.1016/0021-9290(73)90006-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
For small amplitude mechanical excitation at frequencies from 100 to 3000Hz, the response of trabecular bone has no appreciable viscous component. Both fresh wet bone and defatted bone exhibit the same behavior, indicating that the fluid in the intertrabecular spaces has no effect on the dynamic mechanical behavior. Relative stiffness measurements on human trabecular bone correlate well with both trabecular contiguity and volume fraction bone. The correlation with contiguity indicates that plate-bending deformation is important in explaining the mechanical behavior of trabecular bone.