THORACIC ELECTRICAL-IMPEDANCE AND FLUID BALANCE DURING AORTIC-SURGERY

被引:25
作者
JONSSON, F
MADSEN, P
JORGENSEN, LG
LUNDING, M
SECHER, NH
机构
[1] Departments of Anaesthesia and Vascular Surgery, Copenhagen Muscle Research Centre, Rigshospitalet, University of Copenhagen, Copenhagen, DK-2100
关键词
BLOOD GAS MONITORING; BLOOD PRESSURE CATHETERIZATION; SWAN-GANZ; CENTRAL VENOUS PRESSURE; HEART RATE; TEMPERATURE;
D O I
10.1111/j.1399-6576.1995.tb04110.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Indices of fluid balance were evaluated during and after aortic surgery in 16 consecutive patients. Thoracic electrical impedance (TI), heart rate (HR), central venous (CVP), pulmonary artery mean (PAMP), pulmonary wedge (PWP) and mean arterial (MAP) pressure as well as fourteen arterial and venous blood gas variables were followed. Consistent with a reduction of TI by 4.2 (-5.2 to 9.2) Ohm (median and range) during the operation, fluid balance was in excess of 1.8 (-0.1 to 3.3) 1 when evaporation was not taken into account, and it remained elevated by 1.3 (0.0 to 5.4) 1 on the first postoperative morning. The HR, MAP and PWP remained stable, while CVP and PAMP decreased by 6 (-2 to 13) and 6 (-1 to 22) mmHg, respectively. Of the determined variables only TI revealed a meaningful correlation to fluid balance (rho=-0.41; P<0.01). Haemoglobin concentrations increased in proportion to the administered packed erythrocytes, while arterial oxygen saturation, pH and base excess decreased in proportion to the excess fluid. The results indicate that while central venous and pulmonary artery mean pressures gave the impression of a volume deficit, the positive fluid balance was mirrored by thoracic electrical impedance, and that even a minor increase of fluid balance may affect pulmonary function in patients subjected to aortic surgery.
引用
收藏
页码:513 / 517
页数:5
相关论文
共 29 条
[11]   REDUCED LEFT-VENTRICULAR DIAMETERS AT ONSET OF BRADYCARDIA DURING EPIDURAL-ANESTHESIA [J].
JACOBSEN, J ;
SOFELT, S ;
BROCKS, V ;
FERNANDES, A ;
WARBERG, J ;
SECHER, NH .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1992, 36 (08) :831-836
[12]  
JENSTRUP M, 1994, TRANSPLANT P, V26, P1793
[13]   INSENSIBLE PERSPIRATION FROM SKIN UNDER STANDARDIZED ENVIRONMENTAL-CONDITIONS [J].
LAMKE, LO ;
NILSSON, GE ;
REITHNER, HL .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1977, 37 (04) :325-331
[14]  
LAMKE LO, 1977, ACTA CHIR SCAND, V43, P279
[15]   TRANS-THORACIC ELECTRICAL-IMPEDANCE AT 1 AND 100 KHZ - A MEANS FOR SEPARATING THORACIC FLUID COMPARTMENTS [J].
LARSEN, FF ;
MOGENSEN, L ;
TEDNER, B .
CLINICAL PHYSIOLOGY, 1987, 7 (02) :105-113
[16]   CENTRAL VENOUS OXYGEN-SATURATION DURING HYPOVOLEMIC SHOCK IN HUMANS [J].
MADSEN, P ;
IVERSEN, H ;
SECHER, NH .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1993, 53 (01) :67-72
[17]   PERIPHERAL VENOUS OXYGEN-SATURATION DURING HEAD-UP TILT INDUCED HYPOVOLEMIC SHOCK IN HUMANS [J].
MADSEN, P ;
OLESEN, HL ;
KLOKKER, M ;
SECHER, NH .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1993, 53 (04) :411-416
[18]   BLOOD-VOLUME DISTRIBUTION DURING HEAD-UP TILT INDUCED CENTRAL HYPOVOLEMIA IN MAN [J].
MATZEN, S ;
PERKO, G ;
GROTH, S ;
FRIEDMAN, DB ;
SECHER, NH .
CLINICAL PHYSIOLOGY, 1991, 11 (05) :411-422
[19]  
Pawelczyk JA, 1994, BLOOD LOSS SHOCK, P25
[20]   THORACIC IMPEDANCE AS AN INDEX OF BODY-FLUID BALANCE DURING CARDIAC-SURGERY [J].
PERKO, G ;
PERKO, MJ ;
JANSEN, E ;
SECHER, NH .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1991, 35 (07) :568-571