STRIPPING ANALYSIS AT MERCURY MICROELECTRODES IN THE ABSENCE OF SUPPORTING ELECTROLYTE

被引:43
作者
DANIELE, S
MAZZOCCHIN, GA
机构
[1] Department of Physical Chemistry, University of Venice, 1-30123 Venice
关键词
STRIPPING VOLTAMMETRY; CADMIUM; LEAD; MERCURY MICROELECTRODES; WATER;
D O I
10.1016/0003-2670(93)80139-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anodic stripping voltammetry of cadmium and lead in pure water, of conductivity as low as 0.6 muS, was studied at a mercury microelectrode obtained by ex situ deposition of mercury on a 10-mum radius platinum disc electrode. The anodic stripping peaks were investigated in detail to verify the influences of the solution resistance and migration on peak position (E(p)), peak width at half-height (W1/2) and peak current. The results showed that the presence of a small ohmic drop leads to larger W1/2 values than those obtained in the presence of supporting electrolyte, while the peak position varied slightly as a consequence of a change in the liquid junction potential. For concentrations of the metal ion higher than 0.1 muM, a contribution due to migration added to the diffusion current when the samples were examined in the absence of supporting electrolyte. The results were also compared with theoretical predictions; in particular, the effects of migration were studied and transferred to a quantitative basis.
引用
收藏
页码:3 / 11
页数:9
相关论文
共 22 条
[1]   ELECTROCHEMICAL KINETICS AT MICROELECTRODES .4. ELECTROCHEMISTRY IN MEDIA OF LOW IONIC-STRENGTH [J].
AMATORE, C ;
DEAKIN, MR ;
WIGHTMAN, RM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 225 (1-2) :49-63
[2]  
AOKI K, 1981, J ELECTROANAL CHEM, V122, P1
[3]   A TRANSFORMATION FOR THE TREATMENT OF DIFFUSION AND MIGRATION - APPLICATION TO STATIONARY DISK AND HEMISPHERE ELECTRODES [J].
BAKER, DR ;
VERBRUGGE, MW ;
NEWMAN, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 314 (1-2) :23-44
[4]  
BOND AM, 1984, J ELECTROANAL CHEM, V172, P11, DOI 10.1016/0022-0728(84)80172-2
[5]   MICROELECTRODE STUDIES IN THE ABSENCE OF DELIBERATELY ADDED SUPPORTING ELECTROLYTE - SOLVENT DEPENDENCE FOR A NEUTRAL AND SINGLY CHARGED SPECIES [J].
COOPER, JB ;
BOND, AM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 315 (1-2) :143-160
[6]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .2. APPLICATION TO RAIN AND SEA WATERS [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :19-26
[7]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .1. APPLICATION TO WINE [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :9-18
[8]   PREPARATION AND PROPERTIES OF A MERCURY-PLATED IRIDIUM-BASED MICROELECTRODE [J].
DEVITRE, RR ;
TERCIER, ML ;
TSACOPOULOS, M ;
BUFFLE, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :419-425
[9]  
DEWRIES WT, 1967, J ELECTROANAL CHEM, V14, P315
[10]   EFFECT OF THE ELECTRICAL DOUBLE-LAYER ON VOLTAMMETRY AT MICROELECTRODES [J].
NORTON, JD ;
WHITE, HS ;
FELDBERG, SW .
JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (17) :6772-6780