ELECTROMECHANICAL ARTIFICIAL-HEART WITH A NEW GEAR TYPE AND ANGLED PUMP CHAMBERS

被引:4
|
作者
KAUFMANN, R
REUL, H
RAU, G
机构
[1] Helmholtz-Inst. Biomed. Engineering, RWTH, D-5100 Aachen
来源
关键词
TAH-DEVELOPMENT; ANATOMICAL STUDIES; MECHANICAL GEAR DESIGN;
D O I
10.1177/039139889201500807
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The intrathoracic anatomical situation after explantation of the natural heart defines the maximum available space for the design of the housing as well as of the inlet- and outlet connectors of a fully implantable electromechanical artificial heart. Based on computer-assisted anatomical studies, a total artificial heart housing is designed which facilitates an oblique orientation of the pumping chambers for a better fluidmechanical and anatomical arrangement of the in- and outlet connectors. The pumping chamber geometry is based on modifications of an existing cardiac assist-system. Subsequently a mechanical gear which conforms to this anatomically adapted housing is developed.
引用
收藏
页码:481 / 487
页数:7
相关论文
共 50 条
  • [1] TOTAL ARTIFICIAL-HEART IMPLANTATION IN CALVES WITH PUMP OF AN ANGLED PORT DESIGN
    SHAFFER, LJ
    DONACHY, JH
    ROSENBERG, G
    PHILLIPS, WM
    LANDIS, DL
    PROPHET, GA
    OLSEN, E
    ARROWOOD, JA
    PIERCE, WS
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1979, 25 : 254 - 259
  • [2] DEVELOPMENT OF A NEW MOVING-ACTUATOR TYPE ELECTROMECHANICAL TOTAL ARTIFICIAL-HEART
    MIN, BG
    KIM, HC
    LEE, SH
    KIM, IY
    KIM, JW
    CHOI, JW
    KIM, JT
    JUNG, DY
    ARTIFICIAL ORGANS, 1991, 15 (02) : 144 - 146
  • [3] A NEW TYPE OF THE MOTOR-DRIVEN BLOOD PUMP FOR ARTIFICIAL-HEART
    CHEON, GJ
    KIM, HC
    MIN, BG
    HAN, DC
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (04): : 473 - 475
  • [4] LEFT AND RIGHT PUMP OUTPUT CONTROL IN ONE-PIECE ELECTROMECHANICAL TOTAL ARTIFICIAL-HEART
    TAKATANI, S
    SHIONO, M
    SASAKI, T
    ORIME, Y
    SAKUMA, I
    NOON, G
    NOSE, Y
    DEBAKEY, M
    ARTIFICIAL ORGANS, 1993, 17 (03) : 176 - 184
  • [5] ROTARY PUMP ARTIFICIAL-HEART - A NEW SYSTEM FOR CIRCULATORY ASSISTANCE OR HEART REPLACEMENT
    MONTIES, JR
    HAVLIK, P
    MESANA, T
    TRINKL, J
    AUCOMTE, F
    GAUTHIER, T
    LIFE SUPPORT SYSTEMS, 1987, 5 (03): : 251 - 257
  • [6] NEW LIFE FOR THE ARTIFICIAL-HEART
    BENOWITZ, SI
    SCIENCE NEWS, 1984, 126 (22) : 342 - 342
  • [7] PRELIMINARY PROJECT FOR A NEW TYPE OF ELECTROMAGNETIC TOTAL ARTIFICIAL-HEART
    MARTIGNONE, R
    MEDICINA-RIVISTA DELLA ENCICLOPEDIA MEDICA ITALIANA, 1985, 5 (02): : 233 - 234
  • [8] A NEW TOTAL IMPLANTABLE ARTIFICIAL-HEART
    MARTENS, J
    ARTIFICIAL ORGANS, 1990, 14 (04) : 284 - 289
  • [9] DEVELOPMENT OF A TOTALLY IMPLANTABLE ELECTROMECHANICAL TOTAL ARTIFICIAL-HEART - BAYLOR TAH
    TAKATANI, S
    SHIONO, M
    SASAKI, T
    GLUECK, J
    NOON, GP
    NOSE, Y
    DEBAKEY, ME
    ARTIFICIAL ORGANS, 1992, 16 (04) : 398 - 406
  • [10] BIVENTRICULAR ASSIST DEVICES WITH IMPELLER BLOOD PUMPS AND ARTIFICIAL-HEART CHAMBERS
    KEMKES, BM
    HAGER, J
    SCHISTEK, R
    STOSS, F
    PETERS, D
    UNGER, F
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1981, : 71 - 75