The new resin-containing BACTEC 26 Plus blood culturing system (Becton Dickinson Diagnostic Instrument Systems, Towson, Md.) was compared with the Isolator 10 system (Wampole Laboratories, Cranbury, N.J.). Blood samples were drawn by syringe, and equal 10-ml volumes were evaluated in each blood culture system by the recommended methods. Both systems were incubated aerobically with 5% CO2. Of 11,506 acceptable study specimens, 1,788 aerobic isolates were recovered. Overall, recoveries was similar for the two systems, with 626 bacteria or fungi recovered in the BACTEC 26 Plus system only, 499 recovered in the Isolator system only, and 663 recovered in both systems. Of 345 gram-negative rods, 62 grew in the BACTEC system only and 109 grew in the Isolator system only (P < 0.001). Thirty-three of these Isolator-only gram-negative organisms were Acinetobacter spp. Of 209 yeasts, 38 grew in BACTEC only and 81 grew in Isolator only (P < 0.001). Of 200 streptococci and enterococci, 98 were recovered in BACTEC only and 26 grew in Isolator only (P < 0.001). Two hundred twenty-eight independent episodes of gram-negative rod bacteremia occurred. Isolator was the first system positive in 59 of 197 episodes, compared with 45 of 197 for BACTEC when Acinetobacter episodes were excluded. Times to detection were similar for the two systems. High colony counts correlated with repeat positive blood cultures. Isolator and BACTEC had similar overall recoveries, with individual merits and deficiencies for both systems. The additional quantitative information derived from Isolator had utility in our institution.
引用
收藏
页码:2245 / 2249
页数:5
相关论文
共 25 条
[1]   CONTAMINANT BLOOD CULTURES AND RESOURCE UTILIZATION - THE TRUE CONSEQUENCES OF FALSE-POSITIVE RESULTS [J].
BATES, DW ;
GOLDMAN, L ;
LEE, TH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (03) :365-369
[2]   CLINICAL-EVALUATION OF THE LYSIS-CENTRIFUGATION BLOOD CULTURE SYSTEM FOR THE DETECTION OF FUNGEMIA AND COMPARISON WITH A CONVENTIONAL BIPHASIC BROTH BLOOD CULTURE SYSTEM [J].
BILLE, J ;
EDSON, RS ;
ROBERTS, GD .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (02) :126-128
[3]   EVALUATION OF A LYSIS-CENTRIFUGATION SYSTEM FOR RECOVERY OF YEASTS AND FILAMENTOUS FUNGI FROM BLOOD [J].
BILLE, J ;
STOCKMAN, L ;
ROBERTS, GD ;
HORSTMEIER, CD ;
ILSTRUP, DM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (03) :469-471
[4]   LARGE-SCALE CLINICAL COMPARISON OF THE LYSIS-CENTRIFUGATION AND RADIOMETRIC SYSTEMS FOR BLOOD CULTURE [J].
BRANNON, P ;
KIEHN, TE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (06) :951-954
[5]  
BRYAN CS, 1983, REV INFECT DIS, V5, P629
[6]   CLINICAL IMPLICATIONS OF POSITIVE BLOOD CULTURES [J].
BRYAN, CS .
CLINICAL MICROBIOLOGY REVIEWS, 1989, 2 (04) :329-353
[7]   CLINICAL AND BACTERIOLOGIC EVALUATION OF BACTEC RESIN-CONTAINING BLOOD CULTURE-MEDIUM [J].
CALLIHAN, DR ;
MIGNEAULT, PC ;
NOLTE, FS .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1984, 82 (04) :465-469
[8]  
COLTON T, 1974, STAT MED, P207
[9]  
DORN GL, 1979, J CLIN MICROBIOL, V9, P391
[10]   COMPARISON OF DUPONT ISOLATOR AND ROCHE SEPTI-CHEK FOR DETECTION OF FUNGEMIA [J].
GUERRAROMERO, L ;
EDSON, RS ;
COCKERILL, FR ;
HORSTMEIER, CD ;
ROBERTS, GD .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (09) :1623-1625