The Narcotrend monitor

被引:89
作者
Kreuer, S. [1 ]
Wilhelm, W. [2 ]
机构
[1] Univ Saarland, Dept Anaesthesiol & Intens Care Med, D-66421 Homburg, Germany
[2] St Marien Hosp, Dept Anaesthesiol & Intens Care Med, D-44534 Lunen, Germany
关键词
narcotrend; EEG; pattern recognition; narcotrend index;
D O I
10.1016/j.bpa.2005.08.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Narcotrend (MonitorTechnik, Bad Bramstedt, Germany) is an EEG monitor designed to measure the depth of anaesthesia. It has been developed at the University Medical School of Hannover, Germany, has been commercially available for 5 years and has meanwhile received US Food and Drug Administration approval. The Narcotrend algorithm is based on pattern recognition of the raw electroencephalogram (EEG) and classifies the EEG traces into different stages from A (awake) to F (increasing burst suppression down to electrical silence). The newest Narcotrend software version includes a dimensionless Narcotrend index from 100 (awake) to 0 (electrical silence). The raw EEG signal can be recorded by standard electrocardiogram electrodes for single- and double-channel registration. The Narcotrend monitor provides a vast amount of information: the actual Narcotrend stage and index, the trend ('cerebrogram'), the raw EEG signal and a power spectrum and several derived EEG parameters. Multiple clinical and validation studies are available for the Narcotrend monitor, including comparisons with the BIS monitor (Aspect Medical Systems, Natick, USA).
引用
收藏
页码:111 / 119
页数:9
相关论文
共 16 条
[1]  
Bender R, 1992, INFORM CLASSIFICATIO
[2]  
Kraus G, 2000, ANASTH INTENSIVMED, V41, P390
[3]   Narcotrend or bispectral index monitoring during desflurane-remifentanil anesthesia: A comparison with a standard practice protocol [J].
Kreuer, S ;
Bruhn, J ;
Stracke, C ;
Aniset, L ;
Silomon, M ;
Larsen, R ;
Wilhelm, W .
ANESTHESIA AND ANALGESIA, 2005, 101 (02) :427-434
[4]   Comparability of Narcotrend™ index and bispectral index during propofol anaesthesia [J].
Kreuer, S ;
Bruhn, J ;
Larsen, R ;
Bialas, P ;
Wilhelm, W .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 93 (02) :235-240
[5]   Narcotrend monitoring allows faster emergence and a reduction of drug consumption in propofol-remifentanil anesthesia [J].
Kreuer, S ;
Biedler, A ;
Larsen, R ;
Altmann, S ;
Wilhelm, W .
ANESTHESIOLOGY, 2003, 99 (01) :34-41
[6]  
Kreuer S, 2002, ANAESTHESIST, V51, P800, DOI 10.1007/s00101-002-0371-0
[7]   The Narcotrend™ -: a new EEG monitor designed measure the depth of anaesthesia -: A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia [J].
Kreuer, S ;
Biedler, A ;
Larsen, R ;
Schoth, S ;
Altmann, S ;
Wilhelm, W .
ANAESTHESIST, 2001, 50 (12) :921-925
[8]  
Kugler J., 1981, ELEKTROENZEPHALOGRAP
[9]   Cerebral states during sleep, as studied by human brain potentials [J].
Loomis, AL ;
Harvey, EN ;
Hobart, GA .
JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1937, 21 :127-144
[10]   Narcotrend® and Bispectral Index® monitor are superior to classic electroencephalographic parameters for the assessment of anesthetic states during propofol-remifentanil anesthesia [J].
Schmidt, GN ;
Bischoff, P ;
Standl, T ;
Jensen, K ;
Voigt, M ;
Esch, JSA .
ANESTHESIOLOGY, 2003, 99 (05) :1072-1077