AN APPLICATION OF VARIABLE SAMPLING INTERVAL CONTROL CHARTS

被引:65
作者
BAXLEY, RV
机构
[1] Monsanto Fibers Business, Gonzalez, FL
关键词
AVERAGE RUN LENGTH; EXPONENTIALLY WEIGHTED MOVING AVERAGE CONTROL CHARTS; QUALITY COSTS; STATISTICAL PROCESS CONTROL; VARIABLE SAMPLING INTERVALS;
D O I
10.1080/00224065.1995.11979607
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Variable Sampling Interval (VSI) control charts have been studied extensively, and It has been shown for Shewhart, cumulative sum (CUSUM), and exponentially weighted moving average (EWMA) charts that shifts in the process mean can be detected more quickly with no increase in the average in-control sampling or false alarm frequency relative to fixed interval charts. Applications of VSI charts in industry have been few, however, primarily due to logistical problems associated with a variable sample schedule. In this paper, we present an application of a VSI-EWMA chart at Monsanto's nylon fiber plant in Pensacola, Florida. Motivation for this implementation, instead of being quicker detection of shifts, was a significant decrease in laboratory cost with little adverse impact on control chart performance compared with the fixed-interval EWMA chart. The logistical problems were solved by employing a fixed time option with the VSI scheme (VSI-FT), where there is a fixed sample schedule for the long-interval, and in-between samples are taken when warranted by the data.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 14 条
[1]   IMPROVED SWITCHING RULES IN CONTROL PROCEDURES USING VARIABLE SAMPLING INTERVALS [J].
AMIN, RW ;
LETSINGER, WC .
COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 1991, 20 (01) :205-230
[2]   THE SWITCHING BEHAVIOR OF (X)OVER-BAR CHARTS WITH VARIABLE SAMPLING INTERVALS [J].
AMIN, RW ;
HEMASINHA, R .
COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 1993, 22 (07) :2081-2102
[3]  
AMIN RW, 1987, THESIS VIRGINIA POLY
[4]   (X)OVER-BAR CHARTS WITH VARIABLE SAMPLE-SIZE [J].
COSTA, AFB .
JOURNAL OF QUALITY TECHNOLOGY, 1994, 26 (03) :155-163
[5]  
LUCAS JM, 1990, TECHNOMETRICS, V32, P1, DOI 10.2307/1269835
[6]   DEVELOPMENT AND EVALUATION OF CONTROL CHARTS USING EXPONENTIALLY WEIGHTED MOVING AVERAGES [J].
NG, CH ;
CASE, KE .
JOURNAL OF QUALITY TECHNOLOGY, 1989, 21 (04) :242-250
[7]   A COMBINED ADAPTIVE SAMPLE-SIZE AND SAMPLING INTERVAL (X)OVER-BAR CONTROL SCHEME [J].
PRABHU, SS ;
MONTGOMERY, DC ;
RUNGER, GC .
JOURNAL OF QUALITY TECHNOLOGY, 1994, 26 (03) :164-176
[8]  
Reynolds Marion R., 1989, SEQUENTIAL ANAL, V8, P51
[9]  
REYNOLDS MR, 1990, TECHNOMETRICS, V32, P371, DOI 10.2307/1270114
[10]   XBAR CHARTS WITH VARIABLE SAMPLING INTERVALS [J].
REYNOLDS, MR ;
AMIN, RW ;
ARNOLD, JC ;
NACHLAS, JA .
TECHNOMETRICS, 1988, 30 (02) :181-192