DETERMINATION OF BROMATE IN BREAD BY CAPILLARY GAS-CHROMATOGRAPHY WITH A MASS DETECTOR (GC MS)

被引:27
作者
HIMATA, K
KUWAHARA, T
ANDO, S
MARUOKA, H
机构
[1] Yamazaki Baking Co., Ltd, Central Laboratory, Tokyo, 3-15-6 Chitose, Sumida-ku
来源
FOOD ADDITIVES AND CONTAMINANTS | 1994年 / 11卷 / 05期
关键词
BROMATE; BREAD; GAS CHROMATOGRAPHY; MASS DETECTOR;
D O I
10.1080/02652039409374257
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A sensitive method was developed for the determination of bromate in bread by capillary gas chromatography with a mass detector (GC/MS). Bromate was extracted with water from bread samples. After centrifigation, the supernatant was filtered and Cl- was removed by an OnGuard-Ag cartridge column. The mixture was absorbed on a DEA solid phase extraction column and washed with water. Bromate was then eluted with 3 M potassium chloride solution. Two ml of 4 x 10(-3) M styrene monomer solution (washed with 1% sodium hydroxide solution before use), 1 ml 0.01 M potassium bromide solution and 1 ml sulphuric acid were added to the eluent and shaken vigorously. The styrene bromo derivative (alpha-bromomethyl-benzenemethanol[2-bromo-1-phenylethanol]) was extracted with 2 ml n-hexane, and determined by GC/MS. Recoveries of bromate from breads were in the range 91.3-98.1% (0.03-0.50 mug/g), and the limit of detection was 0.03 mug/g. Pullman and open top types of white bread, produced by a sponge and dough method and a short process method respectively, were prepared in our laboratory for measurement of residual bromate. When 30 mug/g or less bromate as HBrO3 (pullman type), and 75 mug/g bromate or less as KBrO3 (open top type), was added to flour, no residual bromate was detected in either type of bread.
引用
收藏
页码:559 / 569
页数:11
相关论文
共 50 条