NONTHORACOTOMY LEAD SYSTEM FOR IMPLANTABLE DEFIBRILLATOR

被引:9
|
作者
BLAKEMAN, BP
SULLIVAN, HJ
MONTOYA, A
CALANDRA, D
WILBER, D
OLSHANSKY, B
KALL, J
KOPP, D
PIFARRE, R
机构
来源
关键词
D O I
10.1016/S0022-5223(19)33975-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Over a 2-year period, 110 patients underwent attempted, implantation of an automatic cardioverter-defibrillator using the nonthoracotomy lead system. Indications included sustained monomorphic ventricular (n = 62), nonsustained with poor ventricular function (n = 7), ventricular fibrillation (n = 21), ventricular tachycardia/fibrillation (n = 18), and familial long QT syndrome (n = 2). There were 90 male and 20 female patients. Mean age was 57 +/- 15 years. Sixty percent had previous coronary bypass or valve operations, or both. Mean left ventricular ejection fraction was 30% +/- 14%, cardiac index was 2.4 +/- 0.9 L/M2, and systolic pulmonary artery pressure was 41 +/- 14 mm Hg. Under general anesthesia, the nonthoracotomy lead was introduced through the left subclavian vein. The subcutaneous patch and generator were placed posteriorly on the serratus muscle and left upper quadrant, respectively. The length of the procedure was 116 +/- 44 minutes and the mean number of defibrillation shocks for a successful implant was 8 +/- 4. Eighty-five patients (77%) had successful implantations. Failures were due to high defibrillation threshold (n = 23) and inability to place a right ventricular lead (n = 2). Predictors of failure included preoperative antiarrhythmic drugs and cardiac index of 1.8 +/- 4 L/M2 or less (p = 0.004). Three patients (2.7%) died after the operation of heart failure (n = 2) and chronic heart transplant rejection (n = 1). Complications included lead migration or dislodgment (n = 8), infection (n = l), and hematoma (n = 3). In summary, the nonthoracotomy lead system may provide an alternative in patients undergoing cardioverter-defibrillator implantation.
引用
收藏
页码:1040 / 1047
页数:8
相关论文
共 50 条
  • [31] Undersensing of ventricular fibrillation in a noncommitted nonthoracotomy cardioverter defibrillator system
    Peralta, AO
    John, RM
    Venditti, FJ
    Martin, DT
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (03): : 610 - 618
  • [32] Subcutaneous implantable cardioverter defibrillator lead displacement
    Vyas, Sandip
    Monkhouse, Christopher
    Srinivasan, Neil
    Lambiase, Pier D.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (04): : 723 - 725
  • [33] Implantable Cardiac Defibrillator Lead Failure and Management
    Swerdlow, Charles D.
    Kalahasty, Gautham
    Ellenbogen, Kenneth A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (11) : 1358 - 1368
  • [34] Implantable cardioverter defibrillator lead diaphragmatic perforation
    Manolis, Athanasios G.
    Chatzis, Dimitrios
    Kouvelas, Konstantinos G.
    EUROPACE, 2009, 11 (02): : 271 - 271
  • [35] Implantable cardioverter-defibrillator lead performance
    Maisel, William H.
    Kramer, Daniel B.
    CIRCULATION, 2008, 117 (21) : 2721 - 2723
  • [36] Incidence of lead system malfunction detected during implantable defibrillator generator replacement
    Goyal, R
    Harvey, M
    Horwood, L
    Bogun, F
    Castellani, M
    Chan, KK
    Daoud, E
    Niebauer, M
    Man, KC
    Morady, F
    Strickberger, SA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (08): : 1143 - 1146
  • [37] Chronic experiences with a single lead dual chamber implantable cardioverter defibrillator system
    Niehaus, M
    De Sousa, M
    Klein, G
    Korte, T
    Pfeiffer, D
    Walles, T
    Raymondos, K
    Tebbenjohanns, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (10): : 1937 - 1943
  • [38] Nonthoracotomy implantable cardioverter defibrillator placement in children:: Use of subcutaneous array leads and abdominally placed implantable cardioverter defibrillators in children
    Gradaus, R
    Hammel, D
    Kotthoff, S
    Böcker, D
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (03) : 356 - 360
  • [39] ELECTROCARDIOGRAPHIC PREDICTORS OF HIGH DEFIBRILLATION THRESHOLDS WITH NONTHORACOTOMY CARDIOVERTER-DEFIBRILLATOR LEAD SYSTEMS
    OSSWALD, S
    TROUTON, TG
    ONUNAIN, SS
    ROELKE, M
    SOSASUAREZ, GE
    MCGOVERN, BA
    GARAN, H
    RUSKIN, JN
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A38 - A38
  • [40] Active Surveillance of the Implantable Cardioverter-Defibrillator Registry for Defibrillator Lead Failures
    Resnic, Frederic S.
    Majithia, Arjun
    Dhruva, Sanket S.
    Ssemaganda, Henry
    Robbins, Susan
    Marinac-Dabic, Danica
    Hewitt, Kathleen
    Ohno-Machado, Lucila
    Reynolds, Matthew R.
    Matheny, Michael E.
    CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2020, 13 (04):