NONTHORACOTOMY LEAD SYSTEM FOR IMPLANTABLE DEFIBRILLATOR

被引:9
|
作者
BLAKEMAN, BP
SULLIVAN, HJ
MONTOYA, A
CALANDRA, D
WILBER, D
OLSHANSKY, B
KALL, J
KOPP, D
PIFARRE, R
机构
来源
关键词
D O I
10.1016/S0022-5223(19)33975-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Over a 2-year period, 110 patients underwent attempted, implantation of an automatic cardioverter-defibrillator using the nonthoracotomy lead system. Indications included sustained monomorphic ventricular (n = 62), nonsustained with poor ventricular function (n = 7), ventricular fibrillation (n = 21), ventricular tachycardia/fibrillation (n = 18), and familial long QT syndrome (n = 2). There were 90 male and 20 female patients. Mean age was 57 +/- 15 years. Sixty percent had previous coronary bypass or valve operations, or both. Mean left ventricular ejection fraction was 30% +/- 14%, cardiac index was 2.4 +/- 0.9 L/M2, and systolic pulmonary artery pressure was 41 +/- 14 mm Hg. Under general anesthesia, the nonthoracotomy lead was introduced through the left subclavian vein. The subcutaneous patch and generator were placed posteriorly on the serratus muscle and left upper quadrant, respectively. The length of the procedure was 116 +/- 44 minutes and the mean number of defibrillation shocks for a successful implant was 8 +/- 4. Eighty-five patients (77%) had successful implantations. Failures were due to high defibrillation threshold (n = 23) and inability to place a right ventricular lead (n = 2). Predictors of failure included preoperative antiarrhythmic drugs and cardiac index of 1.8 +/- 4 L/M2 or less (p = 0.004). Three patients (2.7%) died after the operation of heart failure (n = 2) and chronic heart transplant rejection (n = 1). Complications included lead migration or dislodgment (n = 8), infection (n = l), and hematoma (n = 3). In summary, the nonthoracotomy lead system may provide an alternative in patients undergoing cardioverter-defibrillator implantation.
引用
收藏
页码:1040 / 1047
页数:8
相关论文
共 50 条
  • [21] Performance of the lead system for the Metrix automatic implantable atrial defibrillator
    Jung, W
    Lüderitz, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 513A - 513A
  • [22] The use of a dual shock lead in an implantable atrial defibrillator system
    Kriplen, M
    Ayers, G
    Reuter, D
    PACEMAKER LEADS 1997, 1997, : 573 - 580
  • [23] EPICARDIAL AND NONTHORACOTOMY DEFIBRILLATION LEAD SYSTEMS COMBINED WITH A CARDIOVERTER-DEFIBRILLATOR
    TRAPPE, HJ
    FIEGUTH, HG
    PFITZNER, P
    HEINTZE, J
    WENZLAFF, P
    KIELBLOCK, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (01): : 127 - 132
  • [24] GROSS AND MICROSCOPIC PATHOLOGICAL-CHANGES ASSOCIATED WITH NONTHORACOTOMY IMPLANTABLE DEFIBRILLATOR LEADS
    EPSTEIN, AE
    ANDERSON, PG
    SHEPARD, RB
    PLUMB, VJ
    DAILEY, SM
    KAY, GN
    CIRCULATION, 1994, 90 (04) : 122 - 122
  • [25] LEAD FAILURES IN A NONTHORACOTOMY DEFIBRILLATION LEAD SYSTEM
    HALPERIN, BD
    KRON, J
    OTT, GY
    OLIVER, R
    MCANULTY, JH
    CIRCULATION, 1995, 92 (08) : 717 - 717
  • [26] Noise detection during bradycardia pacing with a hybrid nonthoracotomy implantable cardioverter defibrillator system: Incidence and clinical significance
    Rosenthal, ME
    Paskman, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (07): : 1380 - 1386
  • [27] NONTHORACOTOMY DEFIBRILLATOR LEAD SYSTEMS - A WELCOMED ADDITION BUT STILL A LOT TO LEARN
    MARCHLINSKI, FE
    CIRCULATION, 1993, 87 (04) : 1410 - 1411
  • [28] TRANSVENOUS-SUBCUTANEOUS LEAD SYSTEM FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    HIEF, C
    PODCZECK, A
    VEIT, F
    FROHNER, K
    KALTENBRUNNER, W
    NURNBERG, M
    STEINBACH, K
    WIENER KLINISCHE WOCHENSCHRIFT, 1993, 105 (01) : 12 - 16
  • [29] TRANSVENOUS IMPLANTABLE CARDIOVASCULAR DEFIBRILLATOR LEAD SYSTEM - EXPERIENCE IN 28 PATIENTS
    MATSA, M
    COOPERMAN, I
    VISKIN, S
    GLICK, A
    GUREVITCH, Y
    YAKIREVICH, V
    BELHASSEN, B
    JOURNAL OF CARDIOVASCULAR SURGERY, 1994, 35 (06): : 207 - 209
  • [30] NONTHORACOTOMY LEAD IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - NORMAL RADIOGRAPHIC APPEARANCE
    DALY, BD
    HUMMEL, JD
    LANGBERG, J
    STRICKBERGER, SA
    KALBFLEISCH, S
    MORADY, F
    CASCADE, PN
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) : 749 - 752