NONTHORACOTOMY LEAD SYSTEM FOR IMPLANTABLE DEFIBRILLATOR

被引:9
|
作者
BLAKEMAN, BP
SULLIVAN, HJ
MONTOYA, A
CALANDRA, D
WILBER, D
OLSHANSKY, B
KALL, J
KOPP, D
PIFARRE, R
机构
来源
关键词
D O I
10.1016/S0022-5223(19)33975-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Over a 2-year period, 110 patients underwent attempted, implantation of an automatic cardioverter-defibrillator using the nonthoracotomy lead system. Indications included sustained monomorphic ventricular (n = 62), nonsustained with poor ventricular function (n = 7), ventricular fibrillation (n = 21), ventricular tachycardia/fibrillation (n = 18), and familial long QT syndrome (n = 2). There were 90 male and 20 female patients. Mean age was 57 +/- 15 years. Sixty percent had previous coronary bypass or valve operations, or both. Mean left ventricular ejection fraction was 30% +/- 14%, cardiac index was 2.4 +/- 0.9 L/M2, and systolic pulmonary artery pressure was 41 +/- 14 mm Hg. Under general anesthesia, the nonthoracotomy lead was introduced through the left subclavian vein. The subcutaneous patch and generator were placed posteriorly on the serratus muscle and left upper quadrant, respectively. The length of the procedure was 116 +/- 44 minutes and the mean number of defibrillation shocks for a successful implant was 8 +/- 4. Eighty-five patients (77%) had successful implantations. Failures were due to high defibrillation threshold (n = 23) and inability to place a right ventricular lead (n = 2). Predictors of failure included preoperative antiarrhythmic drugs and cardiac index of 1.8 +/- 4 L/M2 or less (p = 0.004). Three patients (2.7%) died after the operation of heart failure (n = 2) and chronic heart transplant rejection (n = 1). Complications included lead migration or dislodgment (n = 8), infection (n = l), and hematoma (n = 3). In summary, the nonthoracotomy lead system may provide an alternative in patients undergoing cardioverter-defibrillator implantation.
引用
收藏
页码:1040 / 1047
页数:8
相关论文
共 50 条
  • [1] Compatibility of a nonthoracotomy lead system with a biphasic implantable cardioverter-defibrillator
    Porterfield, JG
    Porterfield, LM
    Levine, JH
    Luceri, RM
    Hsia, HH
    AbiSamra, F
    Alvarez, L
    Buxton, AE
    Camm, J
    Cutler, JE
    Fogoros, RN
    Hsia, HH
    Janosik, DL
    Kelly, P
    Levine, JH
    Luceri, RM
    Mann, D
    Meesmann, M
    McCowan, R
    Nathan, A
    Porterfield, JG
    Rothbart, ST
    Steinberg, JS
    Torres, VI
    Trappe, HJ
    Winters, SL
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (08): : 586 - 590
  • [2] A prospective, randomized evaluation of a nonthoracotomy implantable cardioverter defibrillator lead system
    Baker, JH
    Epstein, AE
    VoshageStahl, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01): : 72 - 78
  • [3] IMPLANTATION OF A HYBRID NONTHORACOTOMY IMPLANTABLE DEFIBRILLATOR SYSTEM
    REDD, RM
    BISSETT, JK
    TOBLER, HG
    CLINICAL RESEARCH, 1994, 42 (03): : A362 - A362
  • [4] A PERMANENT TRANSVENOUS LEAD SYSTEM FOR AN IMPLANTABLE PACEMAKER CARDIOVERTER-DEFIBRILLATOR - NONTHORACOTOMY APPROACH TO IMPLANTATION
    YEE, R
    KLEIN, GJ
    LEITCH, JW
    GUIRAUDON, GM
    GUIRAUDON, CM
    JONES, DL
    NORRIS, C
    CIRCULATION, 1992, 85 (01) : 196 - 204
  • [5] Nonthoracotomy implantable defibrillator lead extraction: Results and comparison with extraction of pacemaker leads
    Saad, EB
    Saliba, WI
    Schweikert, RA
    Al-Khadra, AS
    Abdul-Karim, A
    Niebauer, MJ
    Wilkoff, BL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (10): : 1944 - 1950
  • [6] FAILURE OF DEFIBRILLATOR PADDLE AS MIMIC FOR SUBCUTANEOUS PATCH LEAD DURING NONTHORACOTOMY IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEAD CONFIGURATION ASSESSMENT
    PACHULSKI, RT
    KLEIMAN, RB
    JOSEPHSON, ME
    MARCHLINSKI, FE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (09): : 1253 - 1257
  • [7] FAILURE OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR TO REDETECT VENTRICULAR-FIBRILLATION IN PATIENTS WITH A NONTHORACOTOMY LEAD SYSTEM
    JUNG, W
    MANZ, M
    MOOSDORF, R
    LUDERITZ, B
    CIRCULATION, 1992, 86 (04) : 1217 - 1222
  • [8] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IMPLANTED BY NONTHORACOTOMY APPROACH - INITIAL CLINICAL-EXPERIENCE WITH THE REDESIGNED TRANSVENOUS LEAD SYSTEM
    MOORE, SL
    MALONEY, JD
    EDEL, TB
    MCGUINN, WP
    GOHN, D
    MORANT, VA
    TROHMAN, R
    SIMMONS, TW
    WILKOFF, BL
    CASTLE, LW
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 1865 - 1869
  • [9] SUBMAMMARY IMPLANTATION OF A CARDIOVERTER-DEFIBRILLATOR WITH A NONTHORACOTOMY LEAD SYSTEM
    KOLETTIS, TM
    SAXENA, A
    KROL, RB
    SAKSENA, S
    AMERICAN HEART JOURNAL, 1993, 126 (05) : 1222 - 1223
  • [10] RISE IN CHRONIC DEFIBRILLATION THRESHOLDS IN NONTHORACOTOMY IMPLANTABLE DEFIBRILLATOR
    VENDITTI, FJ
    MARTIN, DT
    VASSOLAS, G
    BOWEN, S
    CIRCULATION, 1994, 89 (01) : 216 - 223