SIGNAL-PROCESSING FOR A LASER-DOPPLER BLOOD PERFUSION METER

被引:11
|
作者
KOELINK, MH [1 ]
DEMUL, FFM [1 ]
LEERKOTTE, B [1 ]
GREVE, J [1 ]
JENTINK, HW [1 ]
GRAAFF, R [1 ]
DASSEL, ACM [1 ]
AARNOUDSE, JG [1 ]
机构
[1] UNIV TWENTE,DEPT APPL PHYS,POB 217,7600 AE ENSCHEDE,NETHERLANDS
关键词
DIODE-LASER; LASER-DOPPLER; VELOCIMETRY; ANEMOMETRY; LDA; BLOOD PERFUSION; MICROCIRCULATION; BLOOD FLOW; BLOOD VELOCITY; SIGNAL PROCESSING;
D O I
10.1016/0165-1684(94)90143-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two signal processing methods for laser-Doppler perfusion velocimetry are presented. The methods are based on the calculation of the moments of the frequency power spectrum. The first uses square-root omega-filtering (omega is the frequency) with analogous electronics, the second uses signal autocorrelation with digital electronics. Comparison is made with a third instrument: a spectrum analyzer coupled to a computer, using Fourier transform techniques. The performance of these setups (sensitivity, limit sensitivity and accuracy) are investigated. We propose a calibration standard for signal processors to be used for blood perfusion measurements. The analogous instrument proved to be the cheapest but the digital instrument had the best performance.
引用
收藏
页码:239 / 252
页数:14
相关论文
共 50 条
  • [1] Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination
    Liebert, A
    Leahy, M
    Maniewski, R
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (06) : 740 - 747
  • [2] Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination
    A. Liebert
    M. Leahy
    R. Maniewski
    Medical and Biological Engineering and Computing, 1998, 36 : 740 - 747
  • [3] Blood perfusion hyperaemia in response to graded loading of human heels assessed by laser-Doppler imaging
    Mayrovitz, HN
    Macdonald, J
    Smith, JR
    CLINICAL PHYSIOLOGY, 1999, 19 (05): : 351 - 359
  • [4] SIGNAL-PROCESSING IN ULTRASOUND IMAGING, DOPPLER AND DOPPLER IMAGING
    BURCKHARDT, CB
    ULTRASCHALL IN DER MEDIZIN, 1993, 14 (05): : 220 - 224
  • [5] LASER-DOPPLER VELOCIMETRY AND MONTE-CARLO SIMULATIONS ON MODELS FOR BLOOD PERFUSION IN TISSUE
    DEMUL, FFM
    KOELINK, MH
    KOK, ML
    HARMSMA, PJ
    GREVE, J
    GRAAFF, R
    AARNOUDSE, JG
    APPLIED OPTICS, 1995, 34 (28): : 6595 - 6611
  • [6] INVITRO COMPARISON OF DIFFERENT SIGNAL-PROCESSING ALGORITHMS USED IN LASER DOPPLER FLOWMETRY
    OBEID, AN
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (01) : 43 - 52
  • [7] LASER-DOPPLER IMAGING FOR THE ASSESSMENT OF LIVER PERFUSION DURING TRANSPLANTATION
    SEIFALIAN, AM
    DAVIDSON, BR
    ROLLES, K
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 1993, 5 (06) : 479 - 482
  • [8] HUMAN BRONCHIAL PERFUSION EVALUATED WITH ENDOSCOPIC LASER-DOPPLER FLOWMETRY
    SUNDSET, A
    HANSEN, G
    HAANAES, OC
    LINE, PD
    KVERNEBO, K
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1993, 13 (03): : 233 - 245
  • [9] Peripheral Blood Perfusion Correlates with Microvascular Abnormalities in Systemic Sclerosis: A Laser-Doppler and Nailfold Videocapillaroscopy Study
    Cutolo, Maurizio
    Ferrone, Carmela
    Pizzorni, Carmen
    Soldano, Stefano
    Seriolo, Bruno
    Sulli, Alberto
    JOURNAL OF RHEUMATOLOGY, 2010, 37 (06) : 1174 - 1180
  • [10] Laser Doppler anemometer signal processing for blood flow velocity measurements
    Borozdova, M. A.
    Fedosov, I. V.
    Tuchin, V. V.
    QUANTUM ELECTRONICS, 2015, 45 (03) : 275 - 282