Vortex-assisted ionic liquid microextraction coupled to flame atomic absorption spectrometry for determination of trace levels of cadmium in real samples

被引:83
作者
Chamsaz, Mahmoud [1 ]
Atarodi, Atefe [1 ]
Eftekhari, Mohammad [1 ]
Asadpour, Saeid [1 ]
Adibi, Mina [2 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Chem, Fac Sci, Mashhad, Iran
[2] RIPI, Dept Specialty Chem, Div Chem & Petrochem, Tehran, Iran
关键词
Microextraction; Ionic liquid; Preconcentration; Oxine; Cadmium; Flame atomic absorption spectrometry;
D O I
10.1016/j.jare.2011.12.002
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A simple and rapid vortex assisted ionic liquid based liquid- liquid microextraction technique (VALLME) was proposed for preconcentration of trace levels of cadmium. According to this method, the extraction solvent was dispersed into the aqueous samples by the assistance of vortex agitator. Cadmium preconcentration was mediated by chelation with the 8-hydroxyquinoline (oxine) reagent and an IL, 1-octyl-3-methylimidazolium hexafluorophosphate ([ Omim][ PF6]) was chosen as the extraction solvent to extract the hydrophobic complex. Several variables such as sample pH, concentration of oxine, volume of [ Omim][ PF6] and extraction time were investigated in details and optimum conditions were selected. Under the optimum conditions, the limit of detection (LOD) was 2.9 mu L-1 for Cd () and relative standard deviation (RSD%) for five replicate determinations of 125 mu L-1 was 4.1%. The method was successfully applied to the determination of cadmium in tap water, apple and rice samples. (C)2012 Cairo University. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 39 条
  • [1] Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters
    Aguilera-Herrador, Eva
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1201 (01) : 106 - 111
  • [2] Determination of cadmium in alcohol fuel using Moringa oleifera seeds as a biosorbent in an on-line system coupled to FAAS
    Alves, Vanessa Nunes
    Mosquetta, Rafael
    Melo Coelho, Nivia Maria
    Bianchin, Joyce Nunes
    Di Pietro Roux, Kalya Cravo
    Martendal, Edmar
    Carasek, Eduardo
    [J]. TALANTA, 2010, 80 (03) : 1133 - 1138
  • [3] A new disposable ionic liquid based coating for headspace solid-phase microextraction of methyl tert-butyl ether in a gasoline sample followed by gas chromatography-flame ionization detection
    Amini, Ramin
    Rouhollahi, Ahmad
    Adibi, Mina
    Mehdinia, Ali
    [J]. TALANTA, 2011, 84 (01) : 1 - 6
  • [4] Ionic liquids in analytical chemistry
    Anderson, Jared L.
    Armstrong, Daniel W.
    Wei, Guor-Tzo
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (09) : 2892 - 2902
  • [5] Cloud point extraction for ultra-trace Cd determination in microwave-digested biological samples by ETAAS
    Aranda, Pedro R.
    Gil, Raul A.
    Moyano, Susana
    De Vito, Irma
    Martinez, Luis D.
    [J]. TALANTA, 2008, 77 (02) : 663 - 666
  • [6] Cold-induced aggregation microextraction: A novel sample preparation technique based on ionic liquids
    Baghdadi, Majid
    Shemirani, Farzaneh
    [J]. ANALYTICA CHIMICA ACTA, 2008, 613 (01) : 56 - 63
  • [7] Temperature-controlled ionic liquid-liquid-phase microextraction for the pre-concentration of lead from environmental samples prior to flame atomic absorption spectrometry
    Bai, Huahua
    Zhou, Qingxiang
    Xie, Guohong
    Xiao, Junping
    [J]. TALANTA, 2010, 80 (05) : 1638 - 1642
  • [8] Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water
    Berijani, Sana
    Assadi, Yaghoub
    Anbia, Mansoor
    Milani Hosseini, Mohammad-Reza
    Aghaee, Elham
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) : 1 - 9
  • [9] On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer
    Cerutti, S
    Silva, MF
    Gásquez, JA
    Olsina, RA
    Martinez, LD
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (01) : 43 - 50
  • [10] Preparation of a new Cd(II)-imprinted polymer and its application to determination of cadmium(II) via flow-injection-flame atomic absorption spectrometry
    Gawin, Marta
    Konefal, Jadwiga
    Trzewik, Bartosz
    Walas, Stanislaw
    Tobiasz, Anna
    Mrowiec, Halina
    Witek, Ewa
    [J]. TALANTA, 2010, 80 (03) : 1305 - 1310