DETERMINATION OF TRACE-ELEMENTS IN WATER BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - COLLABORATIVE STUDY

被引:0
作者
LONGBOTTOM, JE
MARTIN, TD
EDGELL, KW
LONG, SE
PLANTZ, MR
WARDEN, BE
BARAONA, R
BENCIVENGO, D
CARDENAS, D
FAIRES, L
GERLACH, D
KING, W
LAING, G
LORD, C
PLANTZ, M
RETTBERG, T
TAN, S
TYE, D
WALLACE, G
机构
[1] BIONET CORP,CINCINNATI,OH 45246
[2] TECHNOL APPLICAT INC,CINCINNATI,OH 45268
[3] WMI ENVIRONM MONITORING LABS,GENEVA,IL
[4] LOCKHEED ENGN & SCI,HOUSTON,TX
[5] US GEOL SURVEY,WASHINGTON,DC 20242
[6] LAWRENCE LIVERMORE NATL LAB,LIVERMORE,CA 94550
[7] PENN BUR LABS,HARRISBURG,PA
[8] PHILLIPS PETR CO,BARTLESVILLE,OK 74004
[9] VG INSTRUMENTS,DANVERS,MA
[10] PERKIN ELMER CORP,NORWALK,CT 06856
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A joint U.S. Environmental Protection Agency (U.S. EPA)-AOAC interlaboratory method validation study was conducted on U.S. EPA method 200.8, Determination of Trace Elements in Waters and Wastes by Inductively Coupled Plasma-Mass Spectrometry. The purpose of the study was to determine and compare the mean recovery and precision of the inductively coupled plasma-mass spectrometry (ICP-MS) analyses for 20 trace elements in reagent water, drinking water, and ground-water. The formal study was based on Youden's nonreplicate plan for collaborative tests of analytical methods. The test waters were spiked with the 20 trace elements at 6 concentration levels in the 0.8-200 mug/L range, prepared as 3 Youden pairs. Thirteen collaborators spiked 100 mL aliquots of the test waters, acidified them with 1 mL concentrated HN03 and 0.5 mL concentrated HCl, reduced the volume to 20 mL by heating in an open beaker at 85-degrees-C, refluxed them for 30 min at 95-degrees-C, and diluted them to 50 mL. After centrifuging or settling the samples, a 20 mL portion of the supernatant was diluted to 50 mL and analyzed by ICP-MS. Related experiments evaluated the method performance in wastewater and wastewater digestate at a single concentration pair, and an alternative nitric acid digestion procedure. Mean recoveries for reagent water, drinking water, and groundwater were generally 95-105% with between-laboratory relative standard deviations about 4-8%. The method also worked well with wastewaters and digestate, with between-laboratory relative standard deviations averaging 8% and recoveries averaging 100%. Recoveries of silver, however, were low in all matrixes at concentrations over 100 mug/L. The nitric acid digestion procedure was comparable in accuracy and precision to the mixed-acid digestion in U.S. EPA method 200.8. The method was adopted first action by AOAC INTERNATIONAL.
引用
收藏
页码:1004 / 1023
页数:20
相关论文
共 12 条
[1]  
[Anonymous], 1986, TEST METHODS EVALUAT
[2]  
BARNETT V, 1984, OUTLIERS STATISTICAL
[3]  
DRAPER NR, 1968, APPLIED REGRESSION A
[4]  
EDGELL KW, 1989, US EPA39 METH
[5]  
LAING GA, 1990, 6020 CLPM US EPA MET
[6]  
LONG SE, 1990, EPA2008 US METH
[7]  
LONG SE, 1990, EPA2008 METH
[8]  
OUTLER EC, 1982, INTERLABORATORY METH
[9]  
Youden W.J., 1975, STAT MANUAL ASS OFFI, P88
[10]  
1990, ANN BOOK ASTM STANDA, V1101