REDUCTION OF INJECTION VARIANCE IN FLOW-INJECTION ANALYSIS

被引:8
|
作者
JOHNSON, BF [1 ]
MALICK, RE [1 ]
DORSEY, JG [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
D O I
10.1016/0039-9140(92)80047-H
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to achieve maximum sensitivity in flow-injection analysis, sample dispersion must be kept to a minimum. This dispersion process, however, is not well understood. Studies of the dispersion process have concentrated on dispersion within the flow manifold while dispersion due to the injection process has been largely ignored. Here sample injection loops packed with inert glass beads and a Serpentine II (distorted) empty loop were constructed and compared to traditional empty sample loops. Digitization of the response curves and subsequent calculation of the statistical moments were used to compare the contribution of each sample loop type to the total system dispersion. Both packed and Serpentine II sample loops were shown to decrease dispersion and increase throughput in flow-injection systems. Plots of peak variance vs. injection volume show variance increasing 1.67 times faster with traditional open sample loops compared to packed loops. When combined with other peak width minimization techniques, this method should further lower concentration limits of detection.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [21] AUTOMATED FLOW-INJECTION ANALYSIS
    ASOUZU, MU
    ALABAMA JOURNAL OF MEDICAL SCIENCES, 1983, 20 (03): : 348 - 348
  • [22] ADVANCES IN FLOW-INJECTION ANALYSIS
    SJODIN, A
    SUNDQVIST, U
    AMERICAN LABORATORY, 1989, 21 (01) : 63 - 67
  • [23] COMMUTATION IN FLOW-INJECTION ANALYSIS
    KRUG, FJ
    BERGAMIN, H
    ZAGATTO, EAG
    ANALYTICA CHIMICA ACTA, 1986, 179 : 103 - 118
  • [24] OPTOSENSING FLOW-INJECTION ANALYSIS
    YERIAN, TD
    CHRISTIAN, GD
    RUZICKA, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 24 - MBTD
  • [25] Flow-injection analysis of pharmaceuticals
    Evgen'ev, MI
    Garmonov, SY
    Shakirova, LS
    JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (04) : 313 - 323
  • [26] FLOW-INJECTION ANALYSIS REVISITED
    MARGOSHES, M
    ANALYTICAL CHEMISTRY, 1982, 54 (06) : A678 - A679
  • [27] RADIOMETRIC FLOW-INJECTION ANALYSIS
    MYINT, U
    TOLGYESSY, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 191 (02): : 413 - 426
  • [28] FLOW-INJECTION ANALYSIS IN THE USSR
    ZOLOTOV, YA
    SHPIGUN, LK
    MICROCHEMICAL JOURNAL, 1992, 45 (02) : 225 - 231
  • [29] EXTRACTION BY FLOW-INJECTION ANALYSIS
    KARLBERG, BI
    THELANDER, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 176 (SEP): : 86 - 86
  • [30] Flow-Injection Analysis of Pharmaceuticals
    M. I. Evgen'ev
    S. Yu. Garmonov
    L. Sh. Shakirova
    Journal of Analytical Chemistry, 2001, 56 : 313 - 323