Optimal Sizing and Analysis of Solar PV, Wind, and Energy Storage Hybrid System for Campus Microgrid

被引:34
作者
Ahmad, Furkan [1 ]
Alam, Mohammad Saad [1 ]
机构
[1] Aligarh Muslim Univ, Dept Elect Engn, Aligarh 202002, Uttar Pradesh, India
关键词
Smart microgrid; optimization; economic analysis; emission analysis;
D O I
10.1080/23080477.2017.1417005
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To mitigate the hazardous effect of increasing energy demand and global warming, the Renewable Energy Sources (RESs)-based smart microgrids are gaining massive attention. However, intermittency, as well as the volatile nature of RESs, make it challengeable task. To confront the wavering of voltage profile and power flow in microgrids, the Energy Storage System (ESS) and Diesel Generators are being used as a backup power supply. On national as well as international scale, a vast list of the Universities with a growing number of departments, centers, and hostels add up a mass amount of energy demand. The study of electricity consumption trend in Aligarh Muslim University (AMU) provides vital information to analyze, design, and implement a suitable solution for the deployment of the microgrid. In this work, Polygeneration based on various smart microgrid topologies in both modes of operation (i.e. grid-connected and off-grid mode) is studied. To execute the economic and feasibility analysis, HOMER (R) is used as simulating and optimizing tool. On the basis of minimum Net Present Cost (NPC) from the various topologies, best solution is recommended. The obtained results show that the total system cost under solar PV + Battery (PV + B) mode is 1419.6 million INR, which is approx. 64.2% higher as compared to the current existing scenario (864.2 million INR), while, the total system cost under (Grid + Solar PV) G + PV mode is 494.92 million, which is approx. 57.2 % lower as compared to the current existing scenario. The comparative study of the environmental and economic structure of proposed topology with existing one reveals that, under the proposed topology, 3.636*106 kg of CO2, 1.578*104 kg of SO2, and 7.7*103 kg of NOX will be mitigated. [GRAPHICS] .
引用
收藏
页码:150 / 157
页数:8
相关论文
共 23 条
[1]   Feasibility study, design and implementation of smart polygeneration microgrid at AMU [J].
Ahmad, Furkan ;
Alam, Mohammad Saad .
SUSTAINABLE CITIES AND SOCIETY, 2017, 35 :309-322
[2]   Developments in xEVs charging infrastructure and energy management system for smart microgrids including xEVs [J].
Ahmad, Furkan ;
Alam, Mohammad Saad ;
Asaad, Mohammad .
SUSTAINABLE CITIES AND SOCIETY, 2017, 35 :552-564
[3]   Performance and Feasibility Analysis of a Grid Interactive Large Scale Wind/PV Hybrid System based on Smart Grid Methodology Case Study South Part - Jordan [J].
Alsafasfeh, Qais H. .
INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2015, 4 (01) :39-47
[4]   Low cost residential microgrid system based home to grid (H2G) back up power management [J].
Amrr, Syed Muhammad ;
Alam, Mohammad Saad ;
Asghar, M. S. Jamil ;
Ahmad, Furkan .
SUSTAINABLE CITIES AND SOCIETY, 2018, 36 :204-214
[5]  
[Anonymous], 2016, MUCH DOES 1MW SOLAR
[6]  
[Anonymous], 2016, EL DEP
[7]  
Asaad M., 2017, P 1 EAI INT C SMART, P1, DOI [10.4108/eai.7-8-2017.152984, DOI 10.4108/EAI.7-8-2017.152984]
[8]   Preliminary investigation on generation of electricity using micro wind turbines placed on a car [J].
Bangi V.K.T. ;
Chaudhary Y. ;
Guduru R.K. ;
Aung K.T. ;
Reddy G.N. .
International Journal of Renewable Energy Development, 2017, 6 (01) :75-81
[9]  
Cristina S., 2009, 3 INT C MAR NAV SCI, P150
[10]   Potential Effect and Analysis of High Residential Solar Photovoltaic (PV) Systems Penetration to an Electric Distribution Utility (DU) [J].
Dellosa, Jeffrey T. .
INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2016, 5 (03) :179-185