VARIATION OF ELECTRON-BEAM UNIFORMITY WITH BEAM ANGULATION AND SCATTERER POSITION FOR TOTAL SKIN IRRADIATION WITH THE STANFORD TECHNIQUE

被引:26
作者
ELKHATIB, E [1 ]
HUSSEIN, S [1 ]
NIKOLIC, M [1 ]
VOSS, NJS [1 ]
PARSONS, C [1 ]
机构
[1] BRITISH COLUMBIA CANC AGCY, DIV RADIAT ONCOL, VANCOUVER, BC V5Z 4E6, CANADA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 02期
关键词
TOTAL SKIN ELECTRON IRRADIATION; STANFORD TECHNIQUE; BEAM SCATTERER-DEGRADERS;
D O I
10.1016/0360-3016(95)00112-C
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The influence of different scatterer-degraders and beam angulations on beam uniformity for total skin electron irradiation using the six dual beam Stanford technique is investigated. Methods and Materials: The 6 MeV high dose rate total skin electron irradiation mode on a linear accelerator was used. Beam profiles and percentage depth doses in the patient plane for single, dual, and six dual beams were measured for different dual beam angulations and acrylic scatterer-degraders of different thicknesses mounted on the treatment head or in front of the patient in the treatment plane. Results: It is demonstrated that, with the same electron nominal energy, total skin irradiation techniques with different beam penetrations can be obtained by inserting various beam scatterer-degraders into the beam, either mounted on the accelerator head or close to the patient. For our patient treatment, a beam penetration was selected so that the 80% dose lay at 8-9 mm and the 50% dose at 15-16 mm depth. This was achieved by mounting a 0.32-cm thick acrylic beam scatterer-degrader on the accelerator head. A uniform vertical profile was obtained for gantry angulations of +/-21 degrees. Conclusions: To implement a total skin electron irradiation technique using the Stanford method, the required depth of penetration needs to be selected. Based on this, the appropriate combination of scatterer-degraders and dual beam angulations to produce a uniform beam in the treatment plane needs to be determined. Different techniques with different beam penetrations can be developed using the same high dose rate mode on the linear accelerator by a proper choice of scatterer-degraders and beam angulations.
引用
收藏
页码:469 / 474
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 1983, MED PHYS, V10, P741
[2]  
BRAHME A, 1976, Medical Physics (Woodbury), V3, P95, DOI 10.1118/1.594210
[3]  
Brahme A, 1981, P S ELECTRON DOSIMET, P45
[4]   DEVELOPMENT OF TOTAL-SKIN ELECTRON THERAPY AT 2 ENERGIES [J].
COX, RS ;
HECK, RJ ;
FESSENDEN, P ;
KARZMARK, CJ ;
RUST, DC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03) :659-669
[5]   DOSIMETRY FOR TOTAL-BODY ELECTRON-BEAM THERAPY IN TREATMENT OF MYCOSIS-FUNGOIDES [J].
EDELSTEIN, GR ;
CLARK, T ;
HOLT, JG .
RADIOLOGY, 1973, 108 (03) :691-694
[6]   A TECHNIQUE FOR TOTAL SKIN ELECTRON-IRRADIATION USING 6 LARGE FLATTENED ELECTRON-BEAMS - IMPLEMENTATION ON LINEAR ACCELERATORS HAVING DIFFERENT MODES OF ELECTRON-BEAM PRODUCTION [J].
ELKHATIB, EG ;
RYMEL, J ;
ALMOKHLEF, J .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (740) :744-748
[7]   REDUCTION OF THE BREMSSTRAHLUNG COMPONENT OF CLINICAL ELECTRON-BEAMS - IMPLICATIONS FOR ELECTRON ARC THERAPY AND TOTAL SKIN ELECTRON-IRRADIATION [J].
ELKHATIB, EE ;
SCRIMGER, J ;
MURRAY, B .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01) :111-118
[8]   SOME PHYSICAL CONSIDERATIONS IN WHOLE SKIN ELECTRON-BEAM THERAPY [J].
HOLT, JG ;
PERRY, DJ .
MEDICAL PHYSICS, 1982, 9 (05) :769-776
[9]  
HOPPE RT, 1979, CANCER TREAT REP, V63, P691
[10]   A TECHNIQUE FOR LARGE-FIELD, SUPERFICIAL ELECTRON THERAPY [J].
KARZMARK, CJ ;
LOEVINGER, R ;
STEELE, RE ;
WEISSBLUTH, M .
RADIOLOGY, 1960, 74 (04) :633-644