THE RELIABILITY OF HICKMAN CATHETER BLOOD FOR THE ASSESSMENT OF ACTIVATION MARKERS OF COAGULATION AND FIBRINOLYSIS IN PATIENTS WITH HEMATOLOGICAL MALIGNANCIES

被引:7
作者
VANGENDEREN, PJJ
GOMES, M
STIBBE, J
机构
[1] Department of Hematology, University Hospital Dijkzigt, Rotterdam
关键词
HICKMAN CATHETER; ACTIVATION MARKER; COAGULATION; FIBRINOLYSIS;
D O I
10.1016/0049-3848(94)90103-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We studied the reliability of Hickman catheter (HC) blood for the determination of activation markers of coagulation and fibrinolysis in 14 patients with hematological malignancies. 10 of 22 HC samples were contaminated with heparin, probably as a consequence of our institutional antithrombotic catheter care, and withdrawn from statistical analysis. Prothrombin activation fragment F1.2, thrombin-antithrombin III complexes, soluble fibrin, degradation products of fibrinogen and fibrin, total degradation products, alpha 2-antiplasmin and antithrombin III levels withdrawn from Hickman catheters did not differ significantly from peripheral venous blood samples. Fibrinogen levels were slightly but significantly higher in peripheral venous blood samples. We conclude that Hickman catheter blood gives reliable results for the determination of activation markers of coagulation and fibrinolysis in patients with hematological malignancies, but may be less useful in clinical practice due to frequent heparin contamination.
引用
收藏
页码:247 / 254
页数:8
相关论文
共 12 条
[1]   COAGULATION-TESTING OF HICKMAN CATHETER BLOOD IN PATIENTS WITH ACUTE-LEUKEMIA [J].
BARTON, JC ;
POON, MC .
ARCHIVES OF INTERNAL MEDICINE, 1986, 146 (11) :2165-2169
[2]  
BLACKLOCK HA, 1980, LANCET, V1, P993
[3]  
BLUME KG, 1978, EXP HEMATOL, V6, P636
[4]   ASSESSMENT OF HYPERCOAGULABLE STATES BY MEASUREMENT OF ACTIVATION FRAGMENTS AND PEPTIDES [J].
BOISCLAIR, MD ;
IRELAND, H ;
LANE, DA .
BLOOD REVIEWS, 1990, 4 (01) :25-40
[5]  
CLAUSS A., 1957, ACTA HAEMATOL, V17, P237
[6]  
FRIBERGER P, 1982, SCAND J CLIN LAB INV, V162, P41
[7]  
HICKMAN RO, 1979, SURG GYNECOL OBSTET, V148, P871
[8]   CATHETER UNSUITABLE FOR THE STUDY OF TURN-OVER PRODUCTS OF COAGULATION, FIBRINOLYSIS AND PLATELET ACTIVATION [J].
HUISVELD, IA ;
VANDENBURG, PJM ;
MEIJER, P ;
VANVLIET, M ;
HOSPERS, JEH ;
MOSTERD, WL ;
BOUMA, BN ;
KLUFT, C .
FIBRINOLYSIS, 1992, 6 :78-80
[9]   DISSEMINATED INTRAVASCULAR COAGULATION IN ACUTE-LEUKEMIA [J].
LISIEWICZ, J .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 1988, 14 (04) :339-350
[10]  
STIBBE J, 1991, THROMB HAEMOSTASIS, V65, P1238