PERFORMANCE OF WIDE-PORE SILICA-BASED AND POLYMER-BASED PACKING MATERIALS IN POLYPEPTIDE SEPARATION - EFFECT OF PORE-SIZE AND ALKYL CHAIN-LENGTH

被引:47
作者
TANAKA, N
KIMATA, K
MIKAWA, Y
HOSOYA, K
ARAKI, T
OHTSU, Y
SHIOJIMA, Y
TSUBOI, R
TSUCHIYA, H
机构
[1] SHISEIDO RES CTR,YOKOHAMA 223,JAPAN
[2] NACALAI TESQUE,MUKO,KYOTO 617,JAPAN
[3] NITTO TECH INFORMAT CTR,IBARAKI 567,JAPAN
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 535卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(01)88932-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effects of pore size and alkyl chain length of silica- and polymer-based packing materials in the elution of polypeptides with an acetonitrile gradient in the presence of trifluoroacetic acid were studied. Considerable differences were found in the performance of alkylsilylated phases prepared from various wide-pore silica particles assumed to have 30-50-nm pores. The pore size of such silica gels was found to be the critical factor in determining the efficiency for high-molecular-weight polypeptides. Silica C18 phases having small pore volumes below 20 nm pore diameter showed comparable performances to C4 and C8 phases for polypeptides with molecular weights of up to 80 000, and were more stable. Polymer-based packing materials with adequate pore size provided excellent column efficiencies and recoveries for polypeptides with higher chemical stabilities than silica-based materials.
引用
收藏
页码:13 / 31
页数:19
相关论文
共 29 条
[1]   SEPARATION OF PROTEINS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. OPTIMIZING THE COLUMN [J].
BURTON, WG ;
NUGENT, KD ;
SLATTERY, TK ;
SUMMERS, BR ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1988, 443 :363-379
[2]   EFFECTS OF CHAIN-LENGTH AND CARBON LOAD ON THE PERFORMANCE OF ALKYL-BONDED SILICAS FOR PROTEIN SEPARATIONS [J].
COOKE, NHC ;
ARCHER, BG ;
OHARE, MJ ;
NICE, EC ;
CAPP, M .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :115-123
[3]  
FRENZ J, 1990, HPLC BIOL MACROMOLEC, pCH6
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF AMINO-ACIDS, PEPTIDES AND PROTEINS .55. STUDIES ON THE ORIGIN OF BAND BROADENING OF POLYPEPTIDES AND PROTEINS SEPARATED BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HEARN, MTW ;
GREGO, B .
JOURNAL OF CHROMATOGRAPHY, 1984, 296 (JUL) :61-82
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF AMINO-ACIDS, PEPTIDES AND PROTEINS .53. EVALUATION OF THE EFFECT OF SEVERAL STATIONARY PHASE PARAMETERS ON THE CHROMATOGRAPHIC-SEPARATION OF POLYPEPTIDES ON ALKYLSILICAS [J].
HEARN, MTW ;
GREGO, B .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :541-560
[6]   PLANARITY RECOGNITION OF LARGE POLYCYCLIC AROMATIC-HYDROCARBONS BY VARIOUS OCTADECYLSILICA STATIONARY PHASES IN NON-AQUEOUS REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
JINNO, K ;
SHIMURA, S ;
TANAKA, N ;
KIMATA, K ;
FETZER, JC ;
BIGGS, WR .
CHROMATOGRAPHIA, 1989, 27 (7-8) :285-291
[7]   CHROMATOGRAPHIC CHARACTERIZATION OF SILICA-C-18 PACKING MATERIALS - CORRELATION BETWEEN A PREPARATION METHOD AND RETENTION BEHAVIOR OF STATIONARY PHASE [J].
KIMATA, K ;
IWAGUCHI, K ;
ONISHI, S ;
JINNO, K ;
EKSTEEN, R ;
HOSOYA, K ;
ARAKI, M ;
TANAKA, N .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (12) :721-728
[8]   SYNTHESIS AND CHARACTERIZATION OF HIGHLY STABLE BONDED PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMN PACKINGS [J].
KIRKLAND, JJ ;
GLAJCH, JL ;
FARLEE, RD .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :2-11
[9]  
KNOX JH, 1984, J CHROMATOGR, V316, P311, DOI 10.1016/S0021-9673(00)96162-4
[10]  
LLOYD LL, 1986, 10TH INT S COL LIQ C