STEREOSELECTIVE DETERMINATION OF FLECAINIDE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION

被引:13
作者
TURGEON, J
KROEMER, HK
PRAKASH, C
BLAIR, IA
RODEN, DM
机构
[1] VANDERBILT UNIV,DEPT PHARMACOL,NASHVILLE,TN 37232
[2] VANDERBILT UNIV,DEPT MED,NASHVILLE,TN 37232
关键词
D O I
10.1002/jps.2600790202
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Enantiomers of a drug may differ in their pharmacological activities or their disposition constants. We now describe a stereoselective analytical method for the determination of the antiarrhythmic agent flecainide in plasma. The resolution of the enantiomers is achieved by high‐performance liquid chromatography (HPLC) on a normal phase silica column following derivatization with the optically active reagent (−)‐menthyl chloroformate. The eluting diastereoisomers are monitored by fluorescence detection at an excitation wavelength of 305 nm and an emission wavelength of 340 nm. The limit of sensitivity for the assay is as low as 2.5 ng/mL for each enantiomer using 1 mL of plasma. A new liquid–liquid extraction procedure with high recovery (>95%) and high selectivity is also reported. The intra‐ and interassay coefficient of variation for replicated analysis of spiked plasma samples is less than 4.0% and 7.0%, respectively. The method is suitable for single and multiple dose pharmacokinetic studies in healthy volunteers or in patients. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:91 / 95
页数:5
相关论文
共 37 条
[1]  
ANDERSON JL, 1984, AM J CARDIOL, V53, pB79, DOI 10.1016/0002-9149(84)90507-1
[2]   ORAL FLECAINIDE ACETATE FOR THE TREATMENT OF VENTRICULAR ARRHYTHMIAS [J].
ANDERSON, JL ;
STEWART, JR ;
PERRY, BA ;
VANHAMERSVELD, DD ;
JOHNSON, TA ;
CONARD, GJ ;
CHANG, SF ;
KVAM, DC ;
PITT, B .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (09) :473-477
[3]  
BANNITT EH, 1986, J MED CHEM, V29, P299
[4]   IS THERE A GENETIC-FACTOR IN FLECAINIDE TOXICITY [J].
BECKMANN, J ;
HERTRAMPF, R ;
GUNDERTREMY, U ;
MIKUS, G ;
GROSS, AS ;
EICHELBAUM, M .
BRITISH MEDICAL JOURNAL, 1988, 297 (6659) :1316-1316
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE MEASUREMENT OF MEXILETINE AND FLECAINIDE IN BLOOD-PLASMA OR SERUM [J].
BHAMRA, RK ;
FLANAGAN, RJ ;
HOLT, DW .
JOURNAL OF CHROMATOGRAPHY, 1984, 307 (02) :439-444
[6]   A RAPID LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF FLECAINIDE IN HUMAN-BLOOD PLASMA USING ULTRAVIOLET DETECTION [J].
BOUTAGY, J ;
RUMBLE, FM ;
SHENFIELD, GM .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (13) :2579-2590
[7]  
CHANG SF, 1983, ARZNEIMITTEL-FORSCH, V33-1, P251
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE QUANTITATION OF FLECAINIDE, A NEW ANTI-ARRHYTHMIC, IN HUMAN-PLASMA AND URINE [J].
CHANG, SF ;
WELSCHER, TM ;
MILLER, AM ;
OBER, RE .
JOURNAL OF CHROMATOGRAPHY, 1983, 272 (02) :341-350
[9]   APPLICATION OF A BONDED-PHASE EXTRACTION COLUMN FOR RAPID SAMPLE PREPARATION OF FLECAINIDE FROM HUMAN-PLASMA FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS - FLUORESCENCE OR ULTRAVIOLET DETECTION [J].
CHANG, SF ;
MILLER, AM ;
FOX, JM ;
WELSCHER, TM .
THERAPEUTIC DRUG MONITORING, 1984, 6 (01) :105-111
[10]   SUPPRESSION OF RESISTANT VENTRICULAR ARRHYTHMIAS BY TWICE DAILY DOSING WITH FLECAINIDE [J].
DUFF, HJ ;
RODEN, DM ;
MAFFUCCI, RJ ;
VESPER, BS ;
CONARD, GJ ;
HIGGINS, SB ;
OATES, JA ;
SMITH, RF ;
WOOSLEY, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (06) :1133-1140