The effect of drying on timber frame connections post flooding

被引:2
作者
Bradley, Alistair [1 ]
Chang, Wen-Shao [1 ]
Harris, Richard [2 ]
机构
[1] Univ Bath, Dept Architecture & Civil Engn, Bath, Avon, England
[2] Univ Bath, Dept Architecture & Civil Engn, BRE Ctr Innovat Construct Mat, Bath, Avon, England
关键词
floods & floodworks; timber structures;
D O I
10.1680/coma.14.00042
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Timber structures face a unique risk from flooding. Elevations in moisture content due to prolonged wetting will lead to a reduction in the mechanical properties of the building. Despite recent growth of timber construction in the UK and a known increased risk from flooding, little research has been conducted into its effects on light frame timber construction and the most efficacious drying method. This paper presents the results of experiments to determine the optimum drying conditions for light timber frame construction with oriented strand board sheathing after simulated flooding. A series of specimens were wetted for 5 d to simulate flooding before exposure to different environments. The specimens were load tested and values of ultimate strength, yield strength and stiffness were compared to those of un-wetted control specimens. It was found that the optimum drying condition for recovery of the maximum pre-wetting mechanical properties was an environment of 38 degrees C and 40% relative humidity. Although this is an optimal setting there is still a permanent reduction in the mechanical properties of approximately 40% for strengths and 20% for stiffness. Stiffness is dependent on grain orientation; however, strength was found to be independent of grain orientation, as it is governed by the oriented strand board failure.
引用
收藏
页码:144 / 157
页数:14
相关论文
共 50 条
  • [31] Rehabilitation of timber structures: novel test method to assess the durability of bonded-in rod connections
    João Custódio
    James Broughton
    Helena Cruz
    Materials and Structures, 2012, 45 : 199 - 221
  • [32] Development of Novel Self-Centering Timber Beam-Column Connections with SMA Bars
    Huang, Jiahao
    Wang, Bin
    Chen, Zhi-Peng
    Zhu, Songye
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (08)
  • [33] Rehabilitation of timber structures: novel test method to assess the durability of bonded-in rod connections
    Custodio, Joao
    Broughton, James
    Cruz, Helena
    MATERIALS AND STRUCTURES, 2012, 45 (1-2) : 199 - 221
  • [34] Experimental studies of timber to cold-formed steel connections with self-drilling screws
    Ng, Adeline Ling Ying
    Lau, Hieng Ho
    Fang, Zhiyuan
    Roy, Krishanu
    Raftery, Gary M.
    Lim, James B. P.
    STRUCTURES, 2023, 49 : 492 - 507
  • [35] Post-flashover fires in light and heavy timber construction compartments
    Hakkarainen, T
    JOURNAL OF FIRE SCIENCES, 2002, 20 (02) : 133 - 175
  • [36] Post-tensioning glulam timber beams with basalt FRP tendons
    McConnell, Emma
    McPolin, Daniel
    Taylor, Su
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CONSTRUCTION MATERIALS, 2015, 168 (05) : 232 - 240
  • [37] Behaviour and repair of carpentry connections - Rotational behaviour of the rafter and tie beam connection in timber roof structures
    Palma, Pedro
    Garcia, Helena
    Ferreira, Joao
    Appleton, Joao
    Cruz, Helena
    JOURNAL OF CULTURAL HERITAGE, 2012, 13 (03) : S64 - S73
  • [38] A numerical and experimental investigation of non-linear deformation behaviours in light-frame timber walls
    Kuai, Le
    Ormarsson, Sigurdur
    Vessby, Johan
    Maharjan, Rajan
    ENGINEERING STRUCTURES, 2022, 252
  • [39] Optimisation of pre/post-stressed embedment-type timber joint
    Shiratori, Takeshi
    Leijten, Adrian J. M.
    Komatsu, Kohei
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2011, 164 (02) : 91 - 104
  • [40] Discussion of Dupleix and Quenneville's 'Investigating brittle failures in multiple-nail steel-to-timber connections
    Beal, N.