GADOLINIUM DTPA ENHANCED MR IMAGING OF ACTH-SECRETING MICROADENOMAS OF THE PITUITARY-GLAND

被引:135
作者
DOPPMAN, JL
FRANK, JA
DWYER, AJ
OLDFIELD, EH
MILLER, DL
NIEMAN, LK
CHROUSOS, GP
CUTLER, GB
LORIAUX, DL
机构
[1] NINCDS,SURG NEUROL BRANCH,BETHESDA,MD 20892
[2] NICHHD,DEV ENDOCRINOL BRANCH,BETHESDA,MD 20892
[3] GEORGETOWN UNIV,MED CTR,DEPT RADIOL,WASHINGTON,DC 20007
关键词
D O I
10.1097/00004728-198809010-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:728 / 735
页数:8
相关论文
共 20 条
[1]   TRANS-SPHENOIDAL MICROSURGICAL MANAGEMENT OF CUSHINGS-DISEASE - REPORT OF 100 CASES [J].
BOGGAN, JE ;
TYRRELL, JB ;
WILSON, CB .
JOURNAL OF NEUROSURGERY, 1983, 59 (02) :195-200
[2]   MICROADENOMAS OF THE PITUITARY AND ABNORMAL SELLAR TOMOGRAMS IN AN UNSELECTED AUTOPSY SERIES [J].
BURROW, GN ;
WORTZMAN, G ;
REWCASTLE, NB ;
HOLGATE, RC ;
KOVACS, K .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 304 (03) :156-158
[3]   REGIONS OF LOW-DENSITY IN THE CONTRAST-ENHANCED PITUITARY-GLAND - NORMAL AND PATHOLOGIC PROCESSES [J].
CHAMBERS, EF ;
TURSKI, PA ;
LAMASTERS, D ;
NEWTON, TH .
RADIOLOGY, 1982, 144 (01) :109-113
[4]   CLINICAL-APPLICATIONS OF CORTICOTROPIN-RELEASING FACTOR [J].
CHROUSOS, GP ;
SCHUERMEYER, TH ;
DOPPMAN, J ;
OLDFIELD, EH ;
SCHULTE, HM ;
GOLD, PW ;
LORIAUX, DL .
ANNALS OF INTERNAL MEDICINE, 1985, 102 (03) :344-358
[5]   POSTERIOR PITUITARY-GLAND - APPEARANCE ON MR IMAGES IN NORMAL AND PATHOLOGICAL STATES [J].
COLOMBO, N ;
BERRY, I ;
KUCHARCZYK, J ;
KUCHARCZYK, W ;
DEGROOT, J ;
LARSON, T ;
NORMAN, D ;
NEWTON, TH .
RADIOLOGY, 1987, 165 (02) :481-485
[6]  
DAVIS PC, 1987, AM J NEURORADIOL, V8, P817
[7]   MR IMAGING OF PITUITARY-ADENOMA - CT, CLINICAL, AND SURGICAL CORRELATION [J].
DAVIS, PC ;
HOFFMAN, JC ;
SPENCER, T ;
TINDALL, GT ;
BRAUN, IF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (04) :797-802
[8]   PETROSAL SINUS SAMPLING FOR CUSHING SYNDROME - ANATOMICAL AND TECHNICAL CONSIDERATIONS [J].
DOPPMAN, JL ;
OLDFIELD, E ;
KRUDY, AG ;
CHROUSOS, GP ;
SCHULTE, HM ;
SCHAAF, M ;
LORIAUX, DL .
RADIOLOGY, 1984, 150 (01) :99-103
[9]   BASILAR VENOUS PLEXUS OF THE POSTERIOR-FOSSA - A POTENTIAL SOURCE OF ERROR IN PETROSAL SINUS SAMPLING [J].
DOPPMAN, JL ;
KRUDY, AG ;
GIRTON, ME ;
OLDFIELD, EH .
RADIOLOGY, 1985, 155 (02) :375-378
[10]   PITUITARY-ADENOMAS IN PATIENTS WITH CUSHING DISEASE - INITIAL EXPERIENCE WITH GD-DTPA-ENHANCED MR IMAGING [J].
DWYER, AJ ;
FRANK, JA ;
DOPPMAN, JL ;
OLDFIELD, EH ;
HICKEY, AM ;
CUTLER, GB ;
LORIAUX, DL ;
SCHIABLE, TF .
RADIOLOGY, 1987, 163 (02) :421-426