AN EXPERIMENTAL THERMAL TIME-CONSTANT CORRELATION FOR HYDRAULIC ACCUMULATORS

被引:52
作者
POURMOVAHED, A
OTIS, DR
机构
[1] Mechanical Engineering Department, University of Wisconsin-Madison, Madison, WI
来源
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME | 1990年 / 112卷 / 01期
关键词
D O I
10.1115/1.2894128
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A thermal time-constant correlation based on experimental data is presented for gascharged hydraulic accumulators. This correlation, along with the thermal timeconstant model, permits accurate prediction of accumulator thermodynamic losses and the gas pressure and temperature history during compression or expansion. The gas is treated as a real gas, and all properties are allowed to vary with both pressure and temperature. The correlation was developed from heat transfer data obtained with a 2.5 liter piston-type accumulator charged with nitrogen gas. Both horizontal and vertical orientations were studied. The experiments covered the range, 2.6×108 <Ra* <9.5×1010, 0.77<L/D<1.50, and 0.71<T*<1.0. The gas pressure was varied between 1.0 and 19.5 MPa. © 1990 by ASME.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 9 条
[1]  
BEACHLEY NH, 1973, 1ST FLUID POW CONTR
[2]  
COOPER HW, 1967, HYDROCARB PROCESS, V46, P141
[3]  
JACOBSEN RT, 1973, NBS648 TECHN NOT
[4]  
KERR CP, 1986, OIL GAS J, V84, P80
[5]   AN ALGORITHM FOR COMPUTING NONFLOW GAS PROCESSES IN GAS SPRINGS AND HYDROPNEUMATIC ACCUMULATORS [J].
OTIS, DR ;
POURMOVAHED, A .
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1985, 107 (01) :93-96
[6]  
OTIS DR, 1973, 1ST FLUID POW CONTR
[7]   EFFECTS OF THERMAL DAMPING ON THE DYNAMIC-RESPONSE OF A HYDRAULIC MOTOR-ACCUMULATOR SYSTEM [J].
POURMOVAHED, A ;
OTIS, DR .
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1984, 106 (01) :21-26
[8]  
POURMOVAHED A, 1985, THESIS U WISCONSIN M
[9]  
SVOBODA J, 1978, FLUID TRANSIENTS ACO