Hemodynamic monitoring is the cornerstone of perioperative anesthetic monitoring. In the unconscious patient, hemodynamic monitoring not only provides information relating to cardiac output, volume status and ultimately tissue perfusion, but also indicates depth of anesthesia and adequacy of pain control. In the 21st century the anesthesiologist has an array of devices to choose from. No single device provides a complete assessment of hemodynamic status, and the use of all devices in every situation is neither practical nor appropriate. This article aims to provide the reader with an overview of the devices currently available, and the information they provide, to assist anesthesiologists in the selection of the most appropriate devices for any given situation. (C) 2012 Published by Elsevier Ltd.
引用
收藏
页码:453 / 462
页数:10
相关论文
共 70 条
[1]   Continuous Non-Invasive Blood Pressure Monitoring, a Validation Study of Nexfin in a Pregnant Population [J].
Akkermans, J. ;
Diepeveen, M. ;
Ganzevoort, W. ;
van Montfrans, G. A. ;
Westerhof, B. E. ;
Wolf, H. .
HYPERTENSION IN PREGNANCY, 2009, 28 (02) :230-242
[2]   Oscillometric sphygmomanometers: a critical appraisal of current technology [J].
Amoore, John Nicholas .
BLOOD PRESSURE MONITORING, 2012, 17 (02) :80-88
[3]   Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study [J].
Benes, Jan ;
Chytra, Ivan ;
Altmann, Pavel ;
Hluchy, Marek ;
Kasal, Eduard ;
Svitak, Roman ;
Pradl, Richard ;
Stepan, Martin .
CRITICAL CARE, 2010, 14 (03)
[4]   Fluid responsiveness predicted by noninvasive Bioreactance-based passive leg raise test [J].
Benomar, Brahim ;
Ouattara, Alexandre ;
Estagnasie, Philippe ;
Brusset, Alain ;
Squara, Pierre .
INTENSIVE CARE MEDICINE, 2010, 36 (11) :1875-1881
[5]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[6]   Equipment review: New techniques for cardiac output measurement - oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis [J].
Berton, C ;
Cholley, B .
CRITICAL CARE, 2002, 6 (03) :216-221
[7]   Evaluation of a New Software Version of the FloTrac/Vigileo (Version 3.02) and a Comparison with Previous Data in Cirrhotic Patients Undergoing Liver Transplant Surgery [J].
Biancofiore, Gianni ;
Critchley, Lester A. H. ;
Lee, Anna ;
Yang, Xiao-xing ;
Bindi, Lucia M. ;
Esposito, Massimo ;
Bisa, Massimo ;
Meacci, Luca ;
Mozzo, Roberto ;
Filipponi, Franco .
ANESTHESIA AND ANALGESIA, 2011, 113 (03) :515-522
[8]   A RANDOMIZED CLINICAL-TRIAL OF THE EFFECT OF DELIBERATE PERIOPERATIVE INCREASE OF OXYGEN DELIVERY ON MORTALITY IN HIGH-RISK SURGICAL PATIENTS [J].
BOYD, O ;
GROUNDS, RM ;
BENNETT, ED .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (22) :2699-2707
[9]   Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia [J].
Cecconi, Maurizio ;
Fasano, Nicola ;
Langiano, Nicola ;
Divella, Michele ;
Costa, Maria G. ;
Rhodes, Andrew ;
Della Rocca, Giorgio .
CRITICAL CARE, 2011, 15 (03)
[10]   Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery [J].
Conway, DH ;
Mayall, R ;
Abdul-Latif, MS ;
Gilligan, S ;
Tackaberry, C .
ANAESTHESIA, 2002, 57 (09) :845-849