GRAPHICAL EXERGY ANALYSIS OF A NEW-TYPE OF ADVANCED CYCLE WITH SATURATED AIR

被引:18
作者
JIN, HG
ISHIDA, M
机构
[1] Research Laboratory of Resources Utilization, Tokyo Institute of Technology, Midoriku, Yokohama, 227
来源
HEAT RECOVERY SYSTEMS & CHP | 1994年 / 14卷 / 02期
关键词
D O I
10.1016/0890-4332(94)90002-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new type of advanced cycle with saturated air called a gas turbine with saturation for air (GTSA) is analyzed by graphical exergy methodology based on energy-utilization diagrams (EUDs). By comparing it with an advanced steam-injected gas turbine cycle (STIG), key features of the GTSA system are clarified. The model system may achieve an efficiency as high as 56%. It is about 8% more efficient than the STIG. In addition, some suggestions are pointed out for further research.
引用
收藏
页码:105 / 116
页数:12
相关论文
共 7 条
[1]  
Jin, Ishida, Graphical exergy analysis of complex cycles, J. Energy—The International Journal, 18, pp. 615-625, (1993)
[2]  
Gasparovic, Stapersma, Gas turbine with heat exchanger and water injection in the compressed air, J. Combustion, pp. 6-16, (1973)
[3]  
Mori, Nakamura, Takahashi, Yamamoto, A Highly Efficient Regenerative Gas-Turbine system with a New Method of Heat Recovery with Water Injection, 1983 Tokyo International Gas Turbine Congress, pp. 297-303, (1983)
[4]  
Cheng, Regenerative Parallel Compound Dual-Fluid Heat Engine, (1978)
[5]  
Cheng, Regenerative Parallel Compound Dual-Fluid Heat Engine, (1978)
[6]  
Ishida, Jin, Graphical Energy Analysis of Significant Role of Humidification Process in a Thermal Power System, 1993 Cracow International Energy Systems and Ecology Congress, (1993)
[7]  
Jin, Ishida, Graphic Presentation of exergy loss in mixing on an energy-utilization diagram, J. Chem. Eng. of Japan, 25, pp. 755-757, (1992)