Corneal spherical aberration and its impact on choosing an intraocular lens for cataract surgery

被引:12
作者
Al-Sayyari, Tarfah M. [1 ]
Fawzy, Samah M. [2 ]
Al-Saleh, Ahmed A. [3 ]
机构
[1] King Saud Univ, POB 231818, Riyadh 11321, Saudi Arabia
[2] Ain Shams Univ, Ophthalmol Dept, Cairo, Egypt
[3] AlHokama Eye Specialist Ctr, Riyadh, Saudi Arabia
关键词
Spherical aberration; Z(4,0); Z(6,0); IOL; Cataract; Corneal aberration; Higher order aberration; Intraocular lens;
D O I
10.1016/j.sjopt.2014.06.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the post operative results of targeting zero spherical aberration by selecting the best-fit aspheric intraocular lens (IOL), based on preoperative corneal spherical aberration of patients with phacoemulsification surgery. Setting: AlHokama Eye Specialist Center, Riyadh, Saudi Arabia. Period: From the 1st of October 2012 until the 10th of April 2013. Methods: Fifty-three eyes, were subjected to phacoemulsification cataract surgery and divided into two groups, 34 eyes were implanted with aspheric IOLs based on their corneal spherical aberration targeting post operative zero total spherical aberration, whereas 19 eyes were implanted with neutral aspheric IOLs regardless of their corneal spherical aberrations (CSAs). As a pre and post routine examination, patients underwent: slit lamp testing, intraocular pressure (IOP) measuring, fundus examination, best spectacle corrected visual acuity (BSCVA), manifest refraction, pupillometry, axial length, contrast sensitivity, and corneal aberration measurement using Pentacam HR (OCULUS, Germany) at the 6-mm optical zone. Post operatively, visual function questionnaire (VF-14) was asked to all patients. Results: Fifty-three eyes of 45 patients, whose age ranged from 45 to 90 years old, were available for analysis, the selected group was implanted with: Tecnis ZA9003 or ZCB00 (Abbott Medical Optics) IOLs in 17 eyes with corneal spherical aberration of more than 0.27 mu m, AcrySof IQ SN60WF (Alcon Laboratories Inc.) IOLs were implanted in 4 eyes with CSA = (0.2-0.27) mu m, and Rayner 970C, 920H or 620H IOLs with spherical aberration (SA) = 0 in 13 eyes with CSA less than 0.20 mu m. The other group of 19 eyes was implanted with aspheric IOLs that have zero spherical aberration (Rayner 970C or 920H) regardless of their CSA. Root mean square (RMS) of total corneal aberration positively correlates to the pupil diameter (P = 0.0031, r = 0.3989). A low negative correlation was found between the corneal spherical aberration of the fourth ordered (Z40) and the axial length (r = -0.2009, P = 0.1492). There was no significant difference between the selected and non-selected group in contrast sensitivity, best spectacle corrected visual acuity, and visual satisfaction (P = 0.5316, P = 0.3919, P = 0.7667). Conclusion: Customized selection of aspheric IOLs based on the eyes' corneal spherical aberration has no significant importance comparing their results with the non-selected group.
引用
收藏
页码:274 / 280
页数:7
相关论文
共 26 条
  • [1] Contrast sensitivity function in pseudophakics and aphakics
    Aggarwal, A
    Khurana, AK
    Nada, M
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 1999, 77 (04): : 441 - 443
  • [2] Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT interocular lenses
    Awwad, Shady T.
    Warmerdam, Dorotheea
    Bowman, R. Wayne
    Dwarakanathan, Surendar
    Cavanagh, H. Dwight
    McCulley, James P.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (06) : 619 - 625
  • [3] Personalized correction of spherical aberration in cataract surgery
    Beiko, George H. H.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08) : 1455 - 1460
  • [4] Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values
    Beiko, George H. H.
    Haigis, Wolfgang
    Steinmueller, Andreas
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) : 848 - 858
  • [5] Bellucci R, 2004, J REFRACT SURG, V20, P297
  • [6] Monochromatic aberrations as a function of age, from childhood to advanced age
    Brunette, I
    Bueno, JM
    Parent, M
    Hamam, H
    Simonet, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (12) : 5438 - 5446
  • [7] ELLIOTT DB, 1992, OPHTHAL PHYSL OPT, V12, P275, DOI 10.1111/j.1475-1313.1992.tb00397.x
  • [8] Corneal aberrations before and after small-incision cataract surgery
    Guirao, A
    Tejedor, J
    Artal, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (12) : 4312 - 4319
  • [9] Wave-front aberrations in the anterior corneal surface and the whole eye
    He, JC
    Gwiazda, J
    Thorn, F
    Held, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (07): : 1155 - 1163
  • [10] Holladay JT, 2002, J REFRACT SURG, V18, P683