SEPARATION OF ENZYMES FROM CANDIDA-BOIDINII CRUDE EXTRACT BY CONTINUOUS-FLOW ZONE ELECTROPHORESIS

被引:17
作者
NATH, S
SCHUTTE, H
WEBER, G
HUSTEDT, H
DECKWER, WD
机构
[1] GESELL BIOTECHNOL FORSCH GMBH,MASCHERODER WEG 1,W-3300 BRAUNSCHWEIG,GERMANY
[2] BENDER & HOBEIN GMBH,MUNICH,GERMANY
关键词
D O I
10.1002/elps.1150111110
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separation of the enzymes formate dehydrogenase, formaldehyde dehydrogenase and methanol oxidase from Candida boidinii crude extract has been explored using continuous flow zone electrophoresis in the VaP‐22 and the scaled‐up VaP‐220 electrophoresis apparatus. Yields up to 95 % and purification factors between 3 and 7 were obtained, together with separation of cell debris from the enzymes. Multiple injections of sample were used to obtain a protein throughput of 46.2 mg/h in the VaP‐22. A tenfold higher throughput was achieved using the VaP‐220. Correlation of the electrophoretic mobility in continuous flow zone electrophoresis with the elution behavior in ion‐exchange chromatography confirmed the primary role of net surface charge in the separation of biological molecules. Proteins and enzymes with differences > 0.05 M elution molarities in ion‐exchange chromatography can be separated. This corresponds to a preparative scale (mg/h or g/h) separation of proteins and enzymes whose difference in apparent electrophoretic mobility is > 0.70 x 10−5cm2/(V.s). Copyright © 1990 VCH Verlagsgesellschaft mbH
引用
收藏
页码:937 / 941
页数:5
相关论文
共 31 条
[1]   PREPARATIVE SEPARATION OF HUMAN-B AND LYMPHOCYTES-T BY FREE-FLOW ELECTROPHORESIS [J].
BAIER, TG ;
WEBER, G ;
HARTMANN, K ;
HEINRICH, U ;
SCHONBERG, D .
ANALYTICAL BIOCHEMISTRY, 1988, 171 (01) :91-95
[2]   THE USE OF FLOW ELECTROPHORESIS IN THE PURIFICATION OF RECOMBINANT HUMAN-TISSUE PLASMINOGEN-ACTIVATOR EXPRESSED IN YEAST [J].
BARTH, F ;
GRUETTER, MG ;
KESSLER, R ;
MANZ, HJ .
ELECTROPHORESIS, 1986, 7 (08) :372-375
[3]  
BASSET P, 1980, ELECTROPHORESIS, V1, P168
[4]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[6]   HIGH-RESOLUTION TWO-DIMENSIONAL POLYACRYLAMIDE-GEL ELECTROPHORESIS .2. ANALYSIS AND APPLICATIONS [J].
DUNN, MJ ;
BURGHES, AHM .
ELECTROPHORESIS, 1983, 4 (03) :173-189
[7]   NEW ASPECTS IN PREPARATIVE AND ANALYTICAL CONTINUOUS FREE-FLOW CELL ELECTROPHORESIS [J].
HANNIG, K .
ELECTROPHORESIS, 1982, 3 (05) :235-243
[8]  
Hannig K, 1974, Methods Enzymol, V31, P746
[9]  
HANNIG K, 1961, Z ANAL CHEM, V181, P244
[10]  
HEIDRICH HG, 1980, EUR J CELL BIOL, V22, P516