SEPARATION OF ENZYMES FROM CANDIDA-BOIDINII CRUDE EXTRACT BY CONTINUOUS-FLOW ZONE ELECTROPHORESIS

被引:17
|
作者
NATH, S
SCHUTTE, H
WEBER, G
HUSTEDT, H
DECKWER, WD
机构
[1] GESELL BIOTECHNOL FORSCH GMBH,MASCHERODER WEG 1,W-3300 BRAUNSCHWEIG,GERMANY
[2] BENDER & HOBEIN GMBH,MUNICH,GERMANY
关键词
D O I
10.1002/elps.1150111110
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separation of the enzymes formate dehydrogenase, formaldehyde dehydrogenase and methanol oxidase from Candida boidinii crude extract has been explored using continuous flow zone electrophoresis in the VaP‐22 and the scaled‐up VaP‐220 electrophoresis apparatus. Yields up to 95 % and purification factors between 3 and 7 were obtained, together with separation of cell debris from the enzymes. Multiple injections of sample were used to obtain a protein throughput of 46.2 mg/h in the VaP‐22. A tenfold higher throughput was achieved using the VaP‐220. Correlation of the electrophoretic mobility in continuous flow zone electrophoresis with the elution behavior in ion‐exchange chromatography confirmed the primary role of net surface charge in the separation of biological molecules. Proteins and enzymes with differences > 0.05 M elution molarities in ion‐exchange chromatography can be separated. This corresponds to a preparative scale (mg/h or g/h) separation of proteins and enzymes whose difference in apparent electrophoretic mobility is > 0.70 x 10−5cm2/(V.s). Copyright © 1990 VCH Verlagsgesellschaft mbH
引用
收藏
页码:937 / 941
页数:5
相关论文
共 50 条
  • [1] Separation of enzymes from microorganism crude extracts by free-flow zone electrophoresis
    Nath, S
    Schutte, H
    Hustedt, H
    Deckwer, WD
    Weber, G
    BIOTECHNOLOGY AND BIOENGINEERING, 1996, 51 (01) : 15 - 22
  • [2] Separation of enzymes from microorganism crude extracts by free-flow zone electrophoresis
    Dept. of Biochem. Eng. and Biotech., Indian Institute of Technology, Hauz Khas, New Delhi 110 016, India
    不详
    不详
    BIOTECHNOL. BIOENG., 1 (15-22):
  • [3] Synchronized, continuous-flow zone electrophoresis
    Zalewski, Dawid R.
    Kohlheyer, Dietrich
    Schlautmann, Stefan
    Gardeniers, Han J. G. E.
    ANALYTICAL CHEMISTRY, 2008, 80 (16) : 6228 - 6234
  • [4] Protein separation by continuous-flow electrophoresis in microgravity
    Lab de Genie Chimique, CNRS URA 192, Universite Paul Sabatier, Toulouse cedex 31062, France
    AIChE J, 7 (2069-2079):
  • [5] Protein separation by continuous-flow electrophoresis in microgravity
    Clifton, MJ
    RouxdeBalmann, H
    Sanchez, V
    AICHE JOURNAL, 1996, 42 (07) : 2069 - 2079
  • [6] IMPROVED OPERATING-CONDITIONS FOR PREPARATIVE SEPARATION OF PROTEINS BY CONTINUOUS-FLOW ZONE ELECTROPHORESIS
    DALENS, F
    ROUXDEBALMANN, H
    SANCHEZ, V
    BIOSEPARATION, 1995, 5 (03) : 127 - 139
  • [7] SEPARATION AND ISOLATION OF MYCOBACTERIAL ANTIGENS BY CONTINUOUS-FLOW ELECTROPHORESIS
    JANICKI, BW
    ARON, SA
    RAYCHAUDHURI, A
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1972, 106 (05): : 779 - +
  • [8] SEPARATION OF HYBRIDOMA CELLS USING CONTINUOUS-FLOW ELECTROPHORESIS
    RUTZKY, LP
    GOODWIN, TJ
    PATHAK, S
    IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY, 1987, 23 (03): : A20 - A20
  • [9] SEPARATION OF AMINO-ACIDS BY CONTINUOUS-FLOW ELECTROPHORESIS
    ZHENG, SN
    SATO, T
    YONEMOTO, T
    TADAKI, T
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1989, 22 (05) : 564 - 567
  • [10] CONTINUOUS-FLOW ELECTROPHORESIS - A SEPARATION CRITERION APPLIED TO THE SEPARATION OF MODEL PROTEINS
    ROUXDEBALMANN, H
    SANCHEZ, V
    JOURNAL OF CHROMATOGRAPHY, 1992, 594 (1-2): : 351 - 359