COMPARISON OF SINUS NODE RESPONSE TO EXERCISE WITH RESPONSES FROM - 2 DIFFERENT ACTIVITY-BASED RATE-ADAPTIVE PACEMAKERS IN HEALTHY-SUBJECTS OF DIFFERENT AGE-GROUPS

被引:7
作者
ROBERTS, DH [1 ]
BAXTER, SE [1 ]
BRENNAN, PT [1 ]
GAMMAGE, MD [1 ]
机构
[1] BIRMINGHAM GEN HOSP, DEPT CARDIOL, BIRMINGHAM, W MIDLANDS, ENGLAND
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 10期
关键词
ACCELEROMETER; PIEZOELECTRIC PACEMAKER; SINUS NODE RESPONSE; HOLTER MONITORING;
D O I
10.1111/j.1540-8159.1995.tb03836.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The pacing rates from accelerometer-based (Excel(TM)) and piezoelectric-based (Legend(TM)) activity sensing rate adaptive pacemakers, both strapped externally in the pectoral position, were compared with sinus rate response in normal volunteers of two different age groups (group 1, mean age 35 +/- 16 years; group 2, mean age 72 +/- 9 years) during various physical activities. Both pacemakers were programmed in manufacturers' nominal rate adaptive settings. Both types of activity sensing pacemakers programmed in this way showed chronotropic deficiencies to metabolic demand in healthy young subjects and in those matching the usual age of pacemaker implant, especially during ''burst'' activities. These data suggest that present recommended activity sensing rate response algorithms for accelerometer and piezoelectric pacemakers are inappropriate for many physical activities.
引用
收藏
页码:1882 / 1888
页数:7
相关论文
共 14 条
[1]   BEHAVIOR OF DIFFERENT ACTIVITY-BASED PACEMAKERS DURING TREADMILL EXERCISE TESTING WITH VARIABLE SLOPES - A COMPARISON OF 3 ACTIVITY-BASED PACING SYSTEMS [J].
ALT, E ;
MATULA, M ;
HOLZER, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :1761-1770
[2]   THE BASIS FOR ACTIVITY CONTROLLED RATE VARIABLE CARDIAC-PACEMAKERS - AN ANALYSIS OF MECHANICAL FORCES ON THE HUMAN-BODY INDUCED BY EXERCISE AND ENVIRONMENT [J].
ALT, E ;
MATULA, M ;
THERES, H ;
HEINZ, M ;
BAKER, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (10) :1667-1680
[3]  
ALT E, 1988, CIRCULATION, V78, P116
[4]   ACTIVITY-BASED PACING - COMPARISON OF A DEVICE USING AN ACCELEROMETER VERSUS A PIEZOELECTRIC CRYSTAL [J].
BACHARACH, DW ;
HILDEN, TS ;
MILLERHAGEN, JO ;
WESTRUM, BL ;
KELLY, JM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (02) :188-196
[5]   COMPARATIVE-EVALUATION OF RATE MODULATION IN NEW GENERATION EVOKED QT AND ACTIVITY SENSING PACEMAKERS [J].
BELLAMY, CM ;
ROBERTS, DH ;
HUGHES, S ;
CHARLES, RG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (07) :993-999
[6]   BENEFIT OF SINGLE SETTING RATE RESPONSIVE VENTRICULAR PACING COMPARED WITH FIXED RATE DEMAND PACING IN ELDERLY PATIENTS [J].
GAMMAGE, M ;
SCHOFIELD, S ;
RANKIN, I ;
BENNETT, M ;
COLES, P ;
PENTECOST, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :174-180
[7]   ACTIVITY-SENSING, RATE-RESPONSIVE PACING - IMPROVEMENT IN MYOCARDIAL PERFORMANCE WITH EXERCISE [J].
HUMEN, DP ;
KOSTUK, WJ ;
KLEIN, GJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (01) :52-59
[8]   LIMITATIONS OF RATE RESPONSE OF AN ACTIVITY-SENSING RATE-RESPONSIVE PACEMAKER TO DIFFERENT FORMS OF ACTIVITY [J].
LAU, CP ;
MEHTA, D ;
TOFF, WD ;
STOTT, RJ ;
WARD, DE ;
CAMM, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (02) :141-150
[9]   RATE ADAPTIVE PACING - CLINICAL-EXPERIENCE WITH 3 DIFFERENT PACING SYSTEMS [J].
MAISCH, B ;
LANGENFELD, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :997-1004
[10]  
MILLERHAGEN J, 1990, PACE, V13, P1204