共 23 条
COMBINATION OF DYNAMIC AND INTEGRAL METHODS FOR GENERATING REPRODUCIBLE FUNCTIONAL CBF IMAGES
被引:140
作者:
LAMMERTSMA, AA
CUNNINGHAM, VJ
DEIBER, MP
HEATHER, JD
BLOOMFIELD, PM
NUTT, J
FRACKOWIAK, RSJ
JONES, T
机构:
[1] MRC Cyclotron Unit, Hammersmith Hospital, London
[2] MRC Cyclotron Unit, Hammersmith Hospital, London W12 0HS, Ducane Road
关键词:
!sup]15[!/sup]O-labelled water;
Delay and dispersion;
Functional images;
Regional cerebral blood flow;
Simulation;
D O I:
10.1038/jcbfm.1990.121
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
A new method to measure regional CBF is presented, applying both dynamic and integral analyses to a dynamic sequence of positron emission tomographic scans collected during and following the administration of H215O (inhalation of C15O2). The dynamic analysis is used to correct continuously monitored arterial whole-blood activity for delay and dispersion relative to tissue scans. An integral analysis including corrections for this delay and dispersion is then used to calculate CBF on a pixel by-pixel basis. Normal values and reproducibility over a 2-h period are presented, together with the results of validation and simulation studies. The results indicate that the single-tissue compartment model adequately describes the distribution of H215O in the brain, without recourse to postulating a nonexchanging water pool.
引用
收藏
页码:675 / 686
页数:12
相关论文