Contrast-enhanced ultrasound compared with multislice computed tomography for endovascular aneurysm repair surveillance

被引:5
作者
Clevert, D-A [1 ]
Sommer, W. H. [1 ]
Meimarakis, G. [2 ]
Kopp, R. [3 ]
Weidenhagen, R. [2 ]
Reiser, M. [1 ]
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Radiol, Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Dept Surg, Munich, Germany
[3] Staedt Klinikum, Klinikum Harlaching, Dept Abdominal & Vasc Surg, Munich, Germany
关键词
Contrast-enhanced ultrasound; multislice computed tomography angiography; abdominal aortic aneurysm; endovascular aneurysm repair;
D O I
10.1258/ult.2010.010043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Endoleaks after endovascular aneurysm repair (EVAR) are commonly encountered and present a diagnostic challenge in the follow-up after EVAR. Contrast-enhanced ultrasound (CEUS) is a new promising method in the diagnosis and follow-up of endoleaks. CEUS with SonoVue w allows a more rapid and non-invasive diagnosis. This review describes the aetiology, classification and importance of different types of endoleaks and compares CEUS findings with multislice computed tomography angiography, thus demonstrating the usefulness of CEUS in this clinical situation.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 41 条
[1]  
Arko FR, 2001, J ENDOVASC THER, V8, P503, DOI 10.1583/1545-1550(2001)008<0503:TIEFEA>2.0.CO
[2]  
2
[3]   Type II lumbar endoleaks: Hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair [J].
Bargellini, I ;
Napoli, V ;
Petruzzi, P ;
Cioni, R ;
Vignali, C ;
Sardella, SG ;
Ferrari, M ;
Bartolozzi, C .
JOURNAL OF VASCULAR SURGERY, 2005, 41 (01) :10-18
[4]  
Baum R A, 2001, Tech Vasc Interv Radiol, V4, P222, DOI 10.1016/S1089-2516(01)90012-5
[5]   Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts [J].
Bendick, PJ ;
Bove, PG ;
Long, GW ;
Zelenock, GB ;
Brown, OW ;
Shanley, CJ .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (02) :381-385
[6]   Endoleak after endovascular repair of abdominal aortic aneurysm [J].
Chuter, TAM ;
Faruqi, RM ;
Sawhney, R ;
Reilly, LM ;
Kerlan, RB ;
Canto, CJ ;
Lukaszewicz, GC ;
LaBerge, JM ;
Wilson, MW ;
Gordon, RL ;
Wall, SD ;
Rapp, J ;
Messina, LM .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (01) :98-105
[7]   Color duplex ultrasound and contrast-enhanced ultrasound in comparison to MS-CT in the detection of endoleak following endovascular aneurysm repair [J].
Clevert, D. -A. ;
Minaifar, N. ;
Weckbach, S. ;
Kopp, R. ;
Meimarakis, G. ;
Clevert, D. -A. ;
Reiser, M. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2008, 39 (1-4) :121-132
[8]   Imaging of aortic abnormalities with contrast-enhanced ultrasound. A pictorial comparison with CT [J].
D.-A. Clevert ;
M. Stickel ;
T. Johnson ;
C. Glaser ;
D.-A. Clevert ;
H. O. Steitz ;
R. Kopp ;
K. W. Jauch ;
M. Reiser .
European Radiology, 2007, 17 (11) :2991-3000
[9]   Contrast-enhanced ultrasound in detection and follow-up of an infrarenal abdominal aortic aneurysm with aorto-caval fistula and endovascular treatment [J].
Clevert, D. -A. ;
Stickel, M. ;
Flach, P. ;
Strautz, T. ;
Horng, A. ;
Jauch, K. W. ;
Reiser, M. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (03) :480-484
[10]   Imaging of endoleaks after endovascular aneurysm repair (EVAR) with contrast-enhanced ultrasound (CEUS). A pictorial comparison with CTA [J].
Clevert, D. -A. ;
Minaifar, N. ;
Kopp, R. ;
Stickel, M. ;
Meimarakis, G. ;
Sommer, W. ;
Reiser, M. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 41 (03) :151-168