METHODS FOR STUDYING CORROSION IN REINFORCED-CONCRETE

被引:78
作者
RODRIGUEZ, P
RAMIREZ, E
GONZALEZ, JA
机构
[1] INST INVEST TECNOL IND & NORMAS TECN,LIMA,PERU
[2] CSIC,CTR NACL INVEST MET,E-28040 MADRID,SPAIN
关键词
D O I
10.1680/macr.1994.46.167.81
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This Paper reviews available techniques for monitoring steel corrosion in reinforced concrete. Electrochemical techniques are by far the most suitable for this purpose, and meet most of the requirements. The responses of direct and alternating current corrosion monitoring methods for steel-concrete systems are compared under two extreme conditions, i.e. steel being corroded in the active state and in the passive state. Most practical situations will belong to one of these or be intermediate to them. Results of polarization resistance measurements (taken by applying a potential step, a current step and small-amplitude cyclovoltammetry), a coulostatic method and electrochemical impedance spectroscopy are reported. It is shown that metal polarization resistance in particular, and electrochemical methods in general, can provide fast and reliable information on the corrosion rate of steel in concrete, sufficiently accurate to distinguish between acceptable and unacceptable conditions in most scientific and technical applications.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 50 条
[21]   MECHANISM OF CORROSION PROTECTION IN REINFORCED-CONCRETE MARINE STRUCTURES [J].
PAGE, CL .
NATURE, 1975, 258 (5535) :514-515
[22]   CORROSION OF REINFORCED-CONCRETE IN THE PERSIAN-GULF REGION [J].
NOVOKSHCHENOV, V .
MATERIALS PERFORMANCE, 1995, 34 (01) :51-54
[23]   CORROSION CONTROL PROCEDURES FOR REINFORCED-CONCRETE POWER MANHOLES [J].
BASHENINI, MS ;
BHANDARI, BM ;
DAVIES, KG .
MATERIALS PERFORMANCE, 1989, 28 (10) :17-24
[24]   ON-SITE DETECTION OF CORROSION IN REINFORCED-CONCRETE STRUCTURES [J].
GONZALEZ, JA ;
FELIU, S ;
ANDRADE, C ;
RODRIGUEZ, I .
MATERIALS AND STRUCTURES, 1991, 24 (143) :346-350
[25]   EARLY CHLORIDE CORROSION OF REINFORCED-CONCRETE - TEST REPORT [J].
ATIMTAY, E ;
FERGUSON, PM .
MATERIALS PERFORMANCE, 1974, 13 (12) :18-21
[26]   CORROSION AND ANTICORROSION PROTECTION OF STRUCTURES BUILT FROM CONCRETE AND REINFORCED-CONCRETE [J].
MOSKVIN, VM ;
IVANOV, FM ;
GUZEEV, EA .
PROTECTION OF METALS, 1979, 15 (02) :205-205
[27]   MARINE CORROSION BEHAVIOR OF REINFORCED-CONCRETE EXPOSED AT TOKYO BAY [J].
MAKITA, M ;
MORI, Y ;
KATAWAKI, K .
JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1980, 77 (05) :381-381
[28]   CORROSION OF STEEL REINFORCEMENT IN POLYPROPYLENE FIBER REINFORCED-CONCRETE STRUCTURES [J].
ALTAYYIB, AHJ ;
ALZAHRANI, MM .
ACI MATERIALS JOURNAL, 1990, 87 (02) :108-113
[29]   CORROSION AND NON-DESTRUCTIVE TESTING IN REINFORCED-CONCRETE STRUCTURES [J].
ISECKE, B .
TECHNISCHES MESSEN, 1988, 55 (04) :152-156
[30]   EFFECT OF CURRENT DISTRIBUTION ON CORROSION RATE MEASUREMENTS IN REINFORCED-CONCRETE [J].
FELIU, S ;
GONZALEZ, JA ;
ANDRADE, C .
CORROSION, 1995, 51 (01) :79-86